Panasonic CS-E18SD3UAW service manual - Page 64
Timer Up Down button
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
Cooling or Dry mode (using remocon function 59) Normal display mode Press SW (t 0secs) Shift -3°C When SW pressed continuously for t 5secs to enter service zone & press SW's to choose function 59 (shift 0°C) Timer Up Down button Shift -1°C Shift 0°C Shift +1°C Shift +3°C Range = -3°C/-2°C/-1°C/0°C/+1°C/+2°C/+3°C Transmit shift code 1 Press SW, special setting is immediately cancelled and normal mode starts. 2 If no SW is pressed for 30secs, then special setting mode is cancelled and normal mode starts. 3 Under this function, only , , & SW's are effective. 64
64
Cooling or Dry mode (using remocon function 59)
Normal display mode
Press
SW (t
0secs)
When
SW pressed continuously for t
5secs to enter service zone
& press
SW’s to choose function 59 (shift 0°C)
Range = -3°C/-2°C/-1°C/0°C/+1°C/+2°C/+3°C
Transmit shift code
Timer Up Down button
Shift -3°C
Shift -1°C
Shift 0°C
Shift +1°C
Shift +3°C
1
Press
SW, special setting is immediately cancelled and normal mode starts.
2
If no SW is pressed for 30secs, then special setting mode is cancelled and normal mode starts.
3
Under this function, only
,
,
&