Panasonic CS-E18SD3UAW service manual - Page 27
Sensor Thermistor, Characteristics, Compressor Temp. Sensor, Thermistor Characteristics
![]() |
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
9.2 Outdoor Unit 9.2.1 CU-E9SD3UA CU-E12SD3UA ELECTRO-MAGNETIC COIL (EXPANSION VALVE) M SINGLE PHASE POWER SUPPLY TO INDOOR UNIT CN-STM (WHT) 1 D29 D28 D27 D26 6 13V C80 G2 L1 YLW/GRN L2 1 2 3 (BLACK) (WHITE) (RED) TERMINAL BOARD REACTOR BLK BLK WHT WHT RED DATA (RED) AC-BLK (BLK) GRY COMMUNICATION CIRCUIT RAT2 (GRY) GRY RAT1 (GRY) FUSE101 20A 250V NOISE FILTER CIRCUIT AC-WHT GRN (WHT) 5V G2 R11 15.8k 1% C6 1u KB 10V G2 R12 15.0k 1% C7 1u KB 10V G2 CN-TH (WHT) 1 2 3 4 G2 PFC CIRCUIT 5V FUSE102 T3.15A L250V FG1 (GRN) 1 GRN LJP101 (GRN) RECTIFICATION CIRCUIT RECTIFICATION CIRCUIT C3 1u KB 10V G2 3 R1 CN-TANK 4.99k 1% (WHT) G2 1 D9 CN-HOT 2 (WHT) FAN MOTOR M 1 4 CN-DCFM (WHT) 7 G2 Q1 FUSE103 T3.15A L250V P N U V W (RED) (BLU) (YLW) SWITCHING POWER SUPPLY CIRCUIT ELECTRONIC CONTROLLER AIR TEMP. SENSOR (THERMISTOR) t˚ t˚ PIPING TEMP. SENSOR (THERMISTOR) COMPRESSOR t˚ TEMP. SENSOR (THERMISTOR) YLW ELECTRO-MAGNETIC COIL (4-WAY VALVE) YLW RED BLU MS YLW 3~ COMPRESSOR Resistance (kΩ) Resistance (kΩ) Sensor (Thermistor) Characteristics 70 1 Outdoor Air Sensor 60 2 Outdoor Heat Exchanger Sensor 50 40 1 30 2 20 10 0 14 32 50 68 86 104 122 Temperature (oF) Compressor Temp. Sensor (Thermistor) Characteristics 70 60 50 40 30 20 10 0 68 104 140 176 212 248 284 Temperature (oF) 27
![](/manual_guide/products/panasonic-e9sd3ua-service-manual-80b38e9/27.png)