Panasonic CS-E18SD3UAW service manual - Page 17

Outdoor Unit

Page 17 highlights

5.2 Outdoor Unit 5.2.1 CU-E9SD3UA CU-E12SD3UA Space necessary for installation 10 cm 10 cm 100 cm 24.4 (15/16) (104.7) (4-3/32) Anchor Bolt Pitch 320 x 570 780 (30-23/32) 570 (22-7/16) 34.5 (1-11/32) 67.6 (2-21/32) 104.9 60.5 (4-1/8) (2-3/8) 84.8 (3-5/16) 155 (6-3/32) 2-way valve at Liquid side (High Pressure) 3-way valve at Gas side (Low Pressure) 11.5 (7/16) 289 (11-13/32) 69.6 61.6 (2-23/32) (2-13/32) (18) (11/16) 542 (21-11/32) Unit : mm/inch 5.2.2 CU-E18SD3UA Space necessary for installation 10 cm 10 cm 100 cm 27.5 (131) (1-1/16) (5-5/32) 875 (34-15/32) 613 (24-1/8) Anchor Bolt Pitch 360.5 x 613 82 (3-7/32) 152 (5-31/32) 360.5 (14-3/16) 38 (1-1/2) 70 (2-3/4) 131 (5-5/32) 2-way valve at Liquid side (High Pressure) 3-way valve at Gas side (Low Pressure) 59 (2-5/16) 320 (12-5/8) 70 75 (2-3/4) (2-15/16) (25) (31-32) 795 (31-5/16) Unit: mm/inch 64 (2-1/2) 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

17
5.2
Outdoor Unit
5.2.1
CU-E9SD3UA
CU-E12SD3UA
Unit : mm/inch
24.4
(15/16)
(104.7)
(4-3/32)
780 (30-23/32)
104.9
(4-1/8)
67.6
(2-21/32)
60.5
(2-3/8)
34.5
(1-11/32)
155 (6-3/32)
84.8
(3-5/16)
570 (22-7/16)
10 cm
100 cm
10 cm
<Top View>
<Front View>
<Side View>
<Side View>
2-way valve at Liquid side
(High Pressure)
3-way valve at Gas side
(Low Pressure)
Anchor Bolt Pitch
320 x 570
Space necessary for
installation
289 (11-13/32)
11.5 (7/16)
542 (21-11/32)
61.6
(2-13/32)
69.6
(2-23/32)
(18)
(11/16)
5.2.2
CU-E18SD3UA
<Top View>
Space necessary for
installation
Anchor Bolt Pitch
360.5 x 613
<Front View>
<Side View>
<Side View>
2-way valve at Liquid side
(High Pressure)
3-way valve at Gas side
(Low Pressure)
Unit: mm/inch
10 cm
100 cm
10 cm
795 (31-5/16)
320 (12-5/8)
59
(2-5/16)
(25)
(31-32)
70
(2-3/4)
75
(2-15/16)
64 (2-1/2)
875 (34-15/32)
27.5
(1-1/16)
38
(1-1/2)
82
(3-7/32)
70
(2-3/4)
360.5 (14-3/16)
613 (24-1/8)
131
(5-5/32)
(131)
(5-5/32)
152