Sharp AR-BC260 AR-BC260 Operation Manual Suite - Page 177

Device control

Page 177 highlights

GENERAL PROGRAMS Device control Use these programs when a peripheral device on the machine has failed or when you wish to temporarily disable a device. The programs can also be used to change the function setting of a device as required by your conditions of use. "Device control" consists of the following programs: GOriginal size detector setting GDisabling of document feeder GDisabling of duplex GDisabling of inverter GDisabling of stapler GDisabling of optional paper drawer GDisabling of large capacity cassette GDisabling of shifter GDisabling of finisher GSaddle stitch position adjust GStream feeding mode GAuto paper selection setting GRegistration adjustment GReturn from copy mode timing Original size detector setting This program is used to select the standard original sizes that can be detected by the original size detection function. Select one of the four groups indicated below. The factory default setting is "INCH-1 (AB-1)". Original size detection by the document glass can also be disabled (CANCEL DETECTION AT DOCUMENT GLASS). Detectable original sizes Group Document feeder tray (for reversing single pass feeding) or document glass 1 INCH - 1 11" x 17", 8-1/2" x 14", 8-1/2" x 11", 8-1/2" x 11"R, 5-1/2" x 8-1/2"* 2 INCH - 2 11" x 17", 8-1/2" x 13", 8-1/2" x 11", 8-1/2" x 11"R, 5-1/2" x 8-1/2"* 3 AB - 1 A3, A4, A4R, A5, B4, B5, B5R 4 AB - 2 A3, A4, A4R, A5, B5, B5R, 8-1/2" x 13" * When the reversing single pass feeder is used, these sizes are only supported for one-sided originals. If "CANCEL DETECTION AT DOCUMENT GLASS" is set, originals will be regarded as EXTRA for all copier functions and no original size will be displayed. Disabling of document feeder This program is used to prevent use of the reversing single pass feeder when it malfunctions. In this case, scanning can still be performed using the document glass. Disabling of duplex This program is used to disable duplex printing when the duplex module malfunctions. If this program is set, only one-sided printing can be performed. Disabling of inverter Use this program when you need to prohibit the inverter function or when the duplex bypass/inverter unit has failed. When the program is turned on, pages are only output face-down to the center tray of the machine. Duplex printing is also not possible (only onesided printing is possible). Disabling of stapler This program is used to disable stapling when the stapler unit of the saddle stitch finisher malfunctions. Disabling of optional paper drawer This program is used to disable use of the stand/1 x 500 sheet paper drawer, stand/3 x 500 sheet paper drawer or duplex module/2 x 500 sheet paper drawer when it malfunctions. NOTE If the duplex module/2 x 500 sheet paper drawer is disabled, automatic two-sided printing cannot be performed. Disabling of large capacity cassette Use this program when you wish to prohibit use of the large capacity cassette or when it has failed. Disabling of shifter Use this program when you need to prohibit the shifter function in the center tray or when the shifter has failed. When the program is turned on, the offset feature that offsets sets of copies or printed pages in the center tray will not function. Disabling of finisher This program is used to disable use of the saddle stitch finisher when it malfunctions. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

11
GENERAL PROGRAMS
Device control
Use these programs when a peripheral device on the
machine has failed or when you wish to temporarily
disable a device. The programs can also be used to
change the function setting of a device as required by
your conditions of use.
"Device control" consists of the following programs:
Original size detector setting
Disabling of document feeder
Disabling of duplex
Disabling of inverter
Disabling of stapler
Disabling of optional paper drawer
Disabling of large capacity cassette
Disabling of shifter
Disabling of finisher
Saddle stitch position adjust
Stream feeding mode
Auto paper selection setting
Registration adjustment
Return from copy mode timing
Original size detector setting
This program is used to select the standard original
sizes that can be detected by the original size detection
function. Select one of the four groups indicated below.
The factory default setting is "INCH-1 (AB-1)". Original
size detection by the document glass can also be
disabled (CANCEL DETECTION AT DOCUMENT
GLASS).
* When the reversing single pass feeder is used, these
sizes are only supported for one-sided originals.
If "CANCEL DETECTION AT DOCUMENT GLASS" is
set, originals will be regarded as EXTRA for all copier
functions and no original size will be displayed.
Disabling of document feeder
This program is used to prevent use of the reversing
single pass feeder when it malfunctions. In this case,
scanning can still be performed using the document
glass.
Disabling of duplex
This program is used to disable duplex printing when
the duplex module malfunctions. If this program is set,
only one-sided printing can be performed.
Disabling of inverter
Use this program when you need to prohibit the
inverter function or when the duplex bypass/inverter
unit has failed. When the program is turned on, pages
are only output face-down to the center tray of the
machine. Duplex printing is also not possible (only one-
sided printing is possible).
Disabling of stapler
This program is used to disable stapling when the
stapler unit of the saddle stitch finisher malfunctions.
Disabling of optional paper drawer
This program is used to disable use of the stand/1 x
500 sheet paper drawer, stand/3 x 500 sheet paper
drawer or duplex module/2 x 500 sheet paper drawer
when it malfunctions.
Disabling of large capacity cassette
Use this program when you wish to prohibit use of the
large capacity cassette or when it has failed.
Disabling of shifter
Use this program when you need to prohibit the shifter
function in the center tray or when the shifter has failed.
When the program is turned on, the offset feature that
offsets sets of copies or printed pages in the center tray
will not function.
Disabling of finisher
This program is used to disable use of the saddle stitch
finisher when it malfunctions.
Group
Detectable original sizes
Document feeder tray (for reversing
single pass feeding) or document glass
1
INCH - 1
11" x 17", 8-1/2" x 14", 8-1/2" x 11",
8-1/2" x 11"R, 5-1/2" x 8-1/2"*
2
INCH - 2
11" x 17", 8-1/2" x 13", 8-1/2" x 11",
8-1/2" x 11"R, 5-1/2" x 8-1/2"*
3
AB - 1
A3, A4, A4R, A5, B4, B5, B5R
4
AB - 2
A3, A4, A4R, A5, B5, B5R, 8-1/2" x 13"
NOTE
If the duplex module/2 x 500 sheet paper drawer is
disabled, automatic two-sided printing cannot be
performed.