Sony PMW320K Product Manual (PMW320 Operating Instruction) - Page 117
Battery, Other, Menu items, Sub-item, Settings, Description, Info/Sony/Other/DC
View all Sony PMW320K manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
MAINTENANCE Menu items Battery Makes settings related to batteries. Sub-item DC In End Detected Battery Type Detection Segment No.10 Segment No.9 Segment No.8 Segment No.7 Segment No.6 Segment No.5 Segment No.4 Segment No.3 Segment No.2 Segment No.1 Settings 11.0V to 14.0V (0.1V step) Info/Sony/Other/DC IN Auto/Other 11.0V to 17.0V (0.1V step) 11.0V to 16.0V to 17.0V (0.1V step) 11.0V to 15.0V to 17.0V (0.1V step) 11.0V to 14.0V to 17.0V (0.1V step) 11.0V to 13.5V to 17.0V (0.1V step) 11.0V to 13.0V to 17.0V (0.1V step) 11.0V to 12.5V to 17.0V (0.1V step) 11.0V to 12.0V to 17.0V (0.1V step) 11.0V to 11.5V to 17.0V (0.1V step) 11.0V to 17.0V (0.1V step) Description Specifies a threshold value that triggers a "Battery End" warning when an external power source is connected to the DC IN connector. Displays the results of automatic battery pack type detection. Auto: Detect the battery type automatically. Other: Fix battery type detection as "Other". Specify voltage threshold values that cause remaining capacity segments to go off in the display of remaining battery capacity (see page 30). (The segments go off below the specified value.) These values are used when the battery type has been found to be "Other". Chapter 6 Menu and Detailed Settings Menu List 117