Adjusting the White Balance, If automatic black balance adjustment, cannot be made
View all Sony PMW320K manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Chapter 3 Adjustments and Settings 1 Set the OUTPUT/DCC switch to CAM. 2 Push the AUTO W/B BAL switch to BLACK and release the switch. The message "Executing..." appears during execution, and changes to "Done" when the adjustment finishes. Adjustment values are saved to memory automatically. Notes • During the black balance adjustment, the iris is automatically closed. • During the black balance adjustment, the gain selection circuit is automatically activated so you may see flickering on the viewfinder screen, but this is not a fault. • Output from the i.LINK connector stops temporarily if you execute black balance adjustment during i.LINK output. Output from the connector resumes when black balance adjustment finishes. If automatic black balance adjustment cannot be made If the black balance adjustment cannot be completed normally, an error message will appear for about three seconds on the viewfinder screen. Possible messages are listed below. Error message NG: Iris Not Closed NG: Timeout NG: Out of Range Meaning The lens iris did not close; adjustment was impossible. Adjustment could not be completed within the standard number of attempts. The difference between the reference value and the current value is so great that it exceeds the range. Adjustment was impossible. If any of the above error messages is displayed, retry the black balance adjustment. If the error message occurs again, an internal check is necessary. For information about this internal check, refer to the Maintenance Manual. Note If the lens cable is not firmly connected to the LENS connector, it may not be possible to adjust the lens iris. If this happens, the black balance will be incorrect. Adjusting the White Balance 1 Set the switches and selectors as shown below. • GAIN switch: L (set to a gain value that is as small as possible) • OUTPUT/DCC switch: CAM • WHITE BAL switch: A or B a) a) Adjustment values are saved to memory B only when OPERATION >White Setting >White Switch in the setup menu, is set to [Memory]. 2 Set the FILTER selector to suit the lighting conditions as follows. 3 Place a white test card under the same lighting conditions as for the subject to be shot and zoom up to it. Alternatively, any white object such as a cloth or a wall can be used. The absolute minimum white area is as follows. Rectangle centered on the screen. The lengths of the sides are 70% of the length and width of the screen. Note Make sure there are not bright spots in the rectangle. 4 Adjust the lens iris. Manually adjusted lens: set the iris to an appropriate setting. Lens with automatic iris: set the automatic/ manual switch on the lens to automatic. 5 Push the AUTO W/B BAL switch to WHITE and then release the switch. Adjusting the Black Balance and the White Balance 51