Sony SRR1000 Product Brochure (SRMASTER: SRR1000 Operation Manual) - Page 44

TC Menu, Button, Indication, Setting, Target, preset, ext-LTC, SDI-LTC, TC & UB, Through, Regene

Page 44 highlights

Chapter 5 Menu Items TC Menu The TC menu allows you to set all of the items related to time codes from a single menu. Button Indication [F1] TCG SRC [F2] REGENE [F3] RUN [F4] DF/NDF [F5] TM SEL [F7] [F8] [F9] [F10] TM RESET TM SET TM HOLD TCR SEL ALT/[F3] TC OUT ALT/[F4] TM DISP Setting Target Selects whether to synchronize the internal time code generator with the external In signal. (see page 27) preset ext-LTC SDI-LTC SDI-VITC Selects the signal to regenerate when the time code generator is in regenerate In mode. TC & UB: Regenerates both the time code signal and user bit signal. TC: Regenerates only the time code signal. UB: Regenerates only the user bit signal. Selects the running mode of the time code generator. In Free: The time code advances when the power is on regardless of the unit's operation mode. Rec: The time code advances only during recording. Selects the drop frame mode of the time code generator or timer counter. I/O DF: Drop frame mode NDF: Non-drop frame mode Notes • This setting is only enabled when the frame frequency of the unit is 29.97 Hz or 59.94 Hz. • This setting is only valid when [F1] (TCG SRC) is set to "preset." Selects the time data to display on the display. To switch between VITC and LTC, I/O press the [F10] (TCR SEL) button. (see page 27) TC UB TM1 TM2 Resets the time counter. I/O Inputs time data. (see page 27) I/O The time counter is temporarily stopped while the button is pressed. Out Sets the value read by the time code reader. Out LTC VITC Sets the time code that is output from the TIME CODE OUT connector during In recording when the internal time code generator is set to a mode for regenerating the playback time code. Through: Outputs the time code signal input from the TIME CODE IN connector as is. Regene: Regenerates the time code signal input from the TIME CODE IN connector before outputting it. Sets whether TM1 is in 12-hour display mode or 24-hour display mode. I/O Note When ±12H is set, the tens digit of the hours value is dropped. +-12H 24H 44 Detailed Menu Description

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

44
Detailed Menu Description
Chapter 5
Menu Items
TC Menu
The TC menu allows you to set all of the items related to
time codes from a single menu.
Button
Indication
Setting
Target
[F1]
TCG SRC
Selects whether to synchronize the internal time code generator with the external
signal.
(see page 27)
preset
ext-LTC
SDI-LTC
SDI-VITC
In
[F2]
REGENE
Selects the signal to regenerate when the time code generator is in regenerate
mode.
TC & UB
:
Regenerates both the time code signal and user bit signal.
TC:
Regenerates only the time code signal.
UB:
Regenerates only the user bit signal.
In
[F3]
RUN
Selects the running mode of the time code generator.
Free
:
The time code advances when the power is on regardless of the unit’s
operation mode.
Rec:
The time code advances only during recording.
In
[F4]
DF/NDF
Selects the drop frame mode of the time code generator or timer counter.
DF
:
Drop frame mode
NDF:
Non-drop frame mode
Notes
This setting is only enabled when the frame frequency of the unit is 29.97 Hz or
59.94 Hz.
This setting is only valid when
[F1]
(TCG SRC) is set to “preset.”
I/O
[F5]
TM SEL
Selects the time data to display on the display. To switch between VITC and LTC,
press the
[F10]
(TCR SEL) button.
(see page 27)
TC
UB
TM1
TM2
I/O
[F7]
TM RESET
Resets the time counter.
I/O
[F8]
TM SET
Inputs time data.
(see page 27)
I/O
[F9]
TM HOLD
The time counter is temporarily stopped while the button is pressed.
Out
[F10]
TCR SEL
Sets the value read by the time code reader.
LTC
VITC
Out
ALT/
[F3]
TC OUT
Sets the time code that is output from the TIME CODE OUT connector during
recording when the internal time code generator is set to a mode for regenerating
the playback time code.
Through
:
Outputs the time code signal input from the TIME CODE IN connector as
is.
Regene:
Regenerates the time code signal input from the TIME CODE IN
connector before outputting it.
In
ALT/
[F4]
TM DISP
Sets whether TM1 is in 12-hour display mode or 24-hour display mode.
Note
When ±12H is set, the tens digit of the hours value is dropped.
+–12H
24H
I/O