Sony SRR1000 Product Brochure (SRMASTER: SRR1000 Operation Manual) - Page 62
Port X Full, Stop Recording, Slot Mx Near End
View all Sony SRR1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Code 1) E201ss Indication2) SLOT Mx NEAR END (Mx NEAR END) E202pp E30100 E302pp PORT x FULL, STOP RECORDING (P-x FULL STOP) KEY INHIBIT (KEY INHIBIT) PORT x REMOTE (P-x REMOTE) 1) The portion in lower case letters in the above codes is one of the following numbers. ss is one of the following numbers which identifies the SRMemory card slot. 01: Slot 1 02: Slot 2 03: Slot 3 04: Slot 4 pp is one of the following numbers which identifies the port. 81: Port A 82: Port B 83: Port C 84: Port D 2) Information inside brackets () indicates the short messages for displaying on the status bar or the superimposed display. Meaning The remaining recording time is less than 5 minutes on the SRMemory card in the indicated slot. The SRMemory card in the indicated port is full and recording was terminated. Button operation is inhibited. The indicated port is remote controlled. Appendix 62 Troubleshooting