Sony SRR1000 Product Brochure (SRMASTER: SRR1000 Operation Manual) - Page 59

Indication, Meaning, PORT x COND3 BAD, STOP REC

Page 59 highlights

Code 1) D5xxss Indication SLOT Mx INTERFACE ERROR1, etc. D6xxss SLOT Mx UNMOUNT ERROR1, etc. D7xxss SLOT Mx MOUNT ERROR1, etc. D801ss SLOT Mx FILE SYSTEM ERROR E101pp PORT x COND3 BAD, STOP REC 1) The portion in lower case letters in the above codes is one of the following numbers. ss is one of the following numbers which identifies the SRMemory card slot. 01: Slot 1 02: Slot 2 03: Slot 3 04: Slot 4 pp is one of the following numbers which identifies the port. 81: Port A 82: Port B 83: Port C 84: Port D xx is the number that identifies the error location. For details, see the Maintenance Manual. zz is the number that identifies the error type. For details, see the Maintenance Manual. Meaning An error occurred when communicating with the SRMemory card in the indicated slot. This SRMemory card cannot be used in its present state. Remove the SRMemory card and insert it again. If the error persists, the unit or the SRMemory card may be damaged. An error occurred when ejecting the SRMemory card from the indicated slot. The ejected SRMemory card may not be available. If the error code D7xxss appears every time the SRMemory card is inserted, the card must be salvaged. Salvage the SRMemory card by following the instructions in the error display screen or remove the card. An error occurred when inserting an SRMemory card into the indicated slot. If the error code D7xxss appears every time the SRMemory card is inserted, the card must be salvaged. Salvage the SRMemory card by following the instructions in the error display screen or remove the card. An error was detected in the file system on the SRMemory card in the indicated slot. If the same error appears every time the SRMemory card is inserted, the card must be formatted. Format the SRMemory card by following the instructions in the error display screen or remove the card. Recording was stopped because all the space for replacing bad sectors is consumed on the SRMemory card inserted in the indicated port. Appendix 59 Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

59
Troubleshooting
Appendix
1) The portion in lower case letters in the above codes is one of the following
numbers.
ss is one of the following numbers which identifies the SRMemory card slot.
01: Slot 1
02: Slot 2
03: Slot 3
04: Slot 4
pp is one of the following numbers which identifies the port.
81: Port A
82: Port B
83: Port C
84: Port D
xx is the number that identifies the error location. For details, see the
Maintenance Manual.
zz is the number that identifies the error type. For details, see the
Maintenance Manual.
D5xxss
SLOT Mx INTERFACE ERROR1, etc.
An error occurred when communicating with the
SRMemory card in the indicated slot.
This SRMemory card cannot be used in its present state.
Remove the SRMemory card and insert it again. If the error
persists, the unit or the SRMemory card may be damaged.
D6xxss
SLOT Mx UNMOUNT ERROR1, etc.
An error occurred when ejecting the SRMemory card from
the indicated slot.
The ejected SRMemory card may not be available. If the
error code D7xxss appears every time the SRMemory card
is inserted, the card must be salvaged.
Salvage the SRMemory card by following the instructions in
the error display screen or remove the card.
D7xxss
SLOT Mx MOUNT ERROR1, etc.
An error occurred when inserting an SRMemory card into
the indicated slot.
If the error code D7xxss appears every time the SRMemory
card is inserted, the card must be salvaged.
Salvage the SRMemory card by following the instructions in
the error display screen or remove the card.
D801ss
SLOT Mx FILE SYSTEM ERROR
An error was detected in the file system on the SRMemory
card in the indicated slot.
If the same error appears every time the SRMemory card is
inserted, the card must be formatted. Format the
SRMemory card by following the instructions in the error
display screen or remove the card.
E101pp
PORT x COND3 BAD, STOP REC
Recording was stopped because all the space for replacing
bad sectors is consumed on the SRMemory card inserted
in the indicated port.
Code
1)
Indication
Meaning