Adaptec 2020ZCR Reference Guide - Page 230
task stop
UPC - 760884151136
View all Adaptec 2020ZCR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 230 highlights
task Commands task stop To stop one or all tasks running on the currently opened controller, use the task stop command. Syntax task stop [/all{=boolean}] Parameters {integer} Specifies the task ID for the task to stop. Perform a task list /all to display the task IDs for all tasks currently running on the open controller before stopping a specific task or all tasks. Switches /all{=boolean} Specifies whether to stop all running tasks. If you set this switch to TRUE, the command stops all tasks that were running on the currently opened controller. If you do not specify this switch or a valid task ID, the command displays an appropriate error message. Examples Before stopping a running task, use the task list command to identify any currently running tasks, as in the following example: AAC0>task list Executing: task list TaskId Function Done% Array 101 Scrub 24.6% 0 State ----RUN Specific1 --------00000000 Specific2 --------00000000 The following example shows the use of the task stop command to stop task 101: AAC0> task stop 101 Executing: task stop 101 8-10