following columns of information, display contains the previous
UPC - 760884151136
View all Adaptec 2020ZCR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 240 highlights
enclosure Commands Examples The following example shows a non-detailed list of components for enclosure management devices 0 and 1: AAC0>enclosure list /all=TRUE Executing: enclosure list /all=TRUE Enclosure Fan Power Slot Sensor Door ScsiId Speaker Standard Diagnostic - 0 115 1 5 0:06:0 No SAF-TE PASSED 1 115 1 5 1:06:0 No SAF-TE PASSED The non-detailed enclosure list display contains the following columns of information: I Enclosure I Fan I Power I Slot I Sensor I Door I ScsiId I Speaker I Standard I Diagnostic The detailed enclosure list display contains the previous columns of information plus the following columns: I EnclosureId I VendorId I ProductId I Firmware The following sections provide brief descriptions of each enclosure list column. 9-7