enclosure Commands enclosure set fan To set the speed of a specific fan on a specific SAF-TE enclosure management device, use the enclosure set fan command. Syntax enclosure set fan [/off{=boolean}] {enclosure} {fan} [{speed}] Parameters {enclosure} Specifies the ID associated with the enclosure management device on which you want to set the speed of a specific fan. For this version, the controller supports a maximum of eight enclosure management devices on each bus. {fan} Specifies the unit number associated with the fan whose speed you want to set. The unit number for the fan ranges from 0 to 15 inclusive. {speed} Specifies the speed at which you want to set this fan. Table 9-3 lists the fan speed values you can specify. Table 9-3 Fan Speed Values Value 0 1 2 3 4 Meaning Turns off the fan Runs the fan at 1/4 the full speed. Runs the fan at 1/2 the full speed. Runs the fan at 3/4 the full speed. Runs the fan at full speed. The fan speed defaults to full speed. 9-15