Adaptec 2020ZCR Reference Guide - Page 275
The Enclosure Column, The Temperature Column, Enclosure, Sensor, Temperature
UPC - 760884151136
View all Adaptec 2020ZCR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 275 highlights
enclosure Commands As the example shows, the temperature sensor status display contains the following columns: I Enclosure I Sensor I Temperature I Threshold I Status The following sections describe the information that the enclosure show temperature command can display in these columns. The Enclosure Column The Enclosure column displays the ID associated with the enclosure management device that you specified on the command line. If you did not specify an ID, the enclosure show temperature command displays the IDs for all enclosure management devices connected to the controller. In the example, 0 is specified. The Sensor Column The Sensor column displays the unit number associated with the temperature sensor that you specified on the command line. If you did not specify a unit number, the enclosure show temperature command displays the unit numbers for all temperature sensors on the enclosure management device or devices. The Temperature Column The Temperature column displays the internal enclosure temperature for this temperature sensor, in degrees Fahrenheit. The temperature can range from -10 degrees to 245 degrees Fahrenheit. In the example, the temperature is 70 degrees Fahrenheit. 9-42