Epson 2070 Service Manual - Page 31
Data Transmission Timing, Table 1-32 Maximum and Minimum Timings for Data Transmission
UPC - 010343812277
View all Epson 2070 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Product Description DATA LC?-2070 Service Manual 'T R O B E ~tsetu~< tstb ! BUSY 1 I &! treadv~l> tbusy ACKNLG I I p-r Figure 1-8 Data Transmission Timing Table 1-32 Maximum and Minimum Timings for Data Transmission Parameter setup thold t stb tready tbusy treply tack tnbusy tnext ttout ttin Minimum 500 nsec 500 nsec 500 nsec 0 -.. -.. 500 nsec o o -.. -.. Maximum 500 nsec -... 10 ~ -... -... 120 nsec 200 nsec 0 The BUSY signal is active (HIGH level) under the conditions below: 0 During data receipt. 0 If the input buffer is full. 0 If the INITsignal is active (LOW level). 0 During hardware initialization. 0 In self-test mode. 0 In adjustment mode. 0 In default-setting mode. 0 The ERROR signal is active (LOW level) under the conditions below: 0 If there is a fatal error. 0 If there is a paper-out error. 0 If the cover is open (cover open error). . PE signal is active (HIGH level) under the conditions below: 0 If there is a paper-out error. 1-22 Rev.A