Epson 2070 Service Manual - Page 90
Removing the CR Motor Assembly, Removing the CR Motor Assembly
UPC - 010343812277
View all Epson 2070 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Disassembly and Assembly LQ-2070 Service Manual 3.2.8 Removing the CR Motor Assembly 1 Remove the rear edge guide assembly, paper eject assembly, rear tractor unit, and printer cover (see Section 3.2.1). 2. Remove the panel board (see Section 3.2.2) and upper housing assembly (see Section 3.2.7). 3. Remove the 2 CR mounting screws securing the CR motor assembly. After releasing the extension spring (15.7 g), disengage the timing belt from the CR motor assembly. 4. Remove 3 CBS screws (3 x 4,F/Zn), 2 CBB screws (3 x 12 F/Zn) securing the upper shield plate main board. 5. Disconnect the cable for CN11 from the C186 MAIN board assembly. 6. Remove the CR motor assembly from the printer mechanism. CR Mounting Screws over the Figure 3-15 Removing the CR Motor Assembly Assembly Notes The tightening torque for the 2 CR mounting screws = 0.78 ~ 0.98 Nm (8~10 Kg - cm) Adjust the bidirectional print alignment. Refer to Chapter 4. 3-12 Rev.A