Epson 2070 Service Manual - Page 93

Removing the PG Sensor Assembly

Page 93 highlights

LQ-2070 Service Manual Disassembly and Assembly 3.2.9.2 Removing the PG Sensor Assembly 1. Remove the rear/front edge guide assembly, front cover, paper eject assembly, rear/front tractor unit, and printer cover (see Section 3.2.1). 2. Remove the panel board (see Section 3.2.2) and upper housing assemblies (see Section 3.2.7). 3. Remove the printer mechanism (see Section 3.2.9 ). 4. Remove the hexagon nut (standard, M4) securing the PG sensor assembly to the right frame assembly. Hexagon Nut(Standard,M4) Figure 3-18 Removing the PG Sensor Assembly Assembly Notes The tightening torque for the hexagon nut (standard, M4) = 1.18 ~ 1.37 Nm (12 ~ 14 Kg f - cm) When securing the shaft, push the front CR guide shaft to the bottom of the cutout. Rev.A 3-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165

3.2.9.2 Removing the PG Sensor Assembly
1.
Remove the rear/front edge guide assembly, front cover, paper eject assembly, rear/front tractor
unit, and printer cover (see Section 3.2.1).
2.
Remove the panel board (see Section 3.2.2) and upper housing assemblies (see Section 3.2.7).
3.
Remove the printer mechanism (see Section 3.2.9 ).
4.
Remove the hexagon nut (standard, M4) securing the PG sensor assembly to the right frame
assembly.
The tightening torque for the hexagon nut (standard, M4)
=
1.18 ~ 1.37 Nm (12 ~ 14 Kg f - cm)
When securing the shaft, push the front CR guide shaft to the bottom of the cutout.
Hexagon Nut(Standard,M4)
Figure 3-18 Removing the PG Sensor Assembly
LQ-2070 Service Manual
Disassembly and Assembly
Rev.A
3-15