Reference Information Modem Reference Information Command +MS=a,b,c,d,e,f +WS=n ECC Commands %Cn +EB=a,b,c +EFCS=0 +ER: a +ER=n +ES=a,b,c +ESR=0 +ETBM=a,b,c FAX Class 1 +FAE=n +FAR=n +FCL=n +FCLASS=n +FIT=n,a +FLO=a Function (Conexant) Select modulation (b, c, d, e, and f are optional). a is the carrier (allowable rates in parentheses): B103 (300), B212 (1200 Rx/75 Tx or 75 Rx/1200 Tx), V21 (300), V22 (1200), V22B (1200/2400), V23C (1200), V32 (4800/9600), V32B (4800-14400), V34 (2400-33600), K56 (32000-56000), V90 (28000-56000), V92 (downstream: 28000-56000; upstream: 24000-48000). b is automode: 0=disabled, 1=enabled (default). c is minimum transmit (Tx) rate (bps). d is maximum transmit rate (bps). e is minimum receive (Rx) rate. f is maximum receive rate (bps). Set PDC mode: 1=disable (default), 20=enable. Set data compression: 0=disable, 1=enable V.42 bis and MNP 5, 2=enable V.42 bis and MNP 5, 3=enable V.42 bis and MNP 5 (default). Select break handling (b and c are optional): a=0 - break is ignored. b=0 - transmitted V.42 L-SIGNAL will not indicate break signal length. c=0 - break is not delivered to DTE. Select 16-bit FCS specified in V.42. Select error control protocol: NONE=error control not in use, LAPM=V.42 LAPM protocol, ALT=MNP. Error control reporting: 0=disable, 1=enable. Select error control and synchronous mode (b and c are optional). a is requested mode when modem is originator: 0=initiate call with direct mode, 1=initiate call with normal mode, 2=initiate V.42 without detection phase, 3=initiate V.42 with detection phase (default), 4=initiate MNP, 6=initiate V.80 synchronous access mode when connection is completed. b specifies fallback mode when modem is originator: 0=LAPM, MNP, or normal mode error control optional (default); 1=LAPM, MNP, or direct mode error control optional; 2=LAPM or MNP error control required; 3=LAPM error control required; 4=MNP error control required. c specifies fallback mode when modem is answerer or specifies V.80 synchronous access mode: 1=error control disabled, use normal mode; 2=LAPM, MNP, or normal mode error control optional (default); 3=LAPM, MNP, or direct mode error control optional; 4=LAPM or MNP error control required; 5=LAPM error control required; 6=MNP error control required; 8=initiate V.80 synchronous access mode when connection complete. Disable selective repeat option in V.42. Handle data remaining in modem buffers on call termination (b and c are optional): a=0 - disconnect occurs immediately and buffered transmit data is discarded. b=0 - disconnect occurs immediately and buffered receive data is discarded. c=0 - modem does not attempt to deliver buffered data and discards data. Data/fax auto answer: 0=disable (default), 1=enable. 0=disable adaptive reception (default), 1=enable. Set loss-of-carrier delay in units of 100 ms (n=0 to 255). Set active service class: 0=data mode (default), 1=Fax Class 1, 1.0=Fax Class 1.0 mode, 8=voice mode. Set DTE inactivity timeout n seconds after which modem goes on-hook (a=0) or DCE goes on hook (a=1). Set flow control type: 0=XON/XOFF and RTS/CTS flow control turned off; 1=XON/XOFF flow control in either direction; 2=RTS for flow control of modem by DTE, and CTS for flow control of DTE by modem. Reference Guide 143

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

Reference Information
Modem Reference Information
Reference Guide
143
Command
Function (Conexant)
+MS=
a
,
b
,
c
,
d
,
e
,
f
Select modulation (
b
,
c
,
d
,
e
, and
f
are optional).
a
is the carrier (allowable rates in parentheses): B103 (300), B212 (1200 Rx/75 Tx or 75 Rx/1200 Tx),
V21 (300), V22 (1200), V22B (1200/2400), V23C (1200), V32 (4800/9600), V32B (4800–14400), V34
(2400–33600), K56 (32000–56000), V90 (28000–56000), V92 (downstream: 28000–56000; upstream:
24000–48000).
b
is automode: 0=disabled, 1=enabled (default).
c
is minimum transmit (Tx) rate (bps).
d
is maximum transmit rate (bps).
e
is minimum receive (Rx) rate.
f
is maximum receive rate (bps).
+WS=
n
Set PDC mode: 1=disable (default), 20=enable.
ECC Commands
%C
n
Set data compression: 0=disable, 1=enable V.42 bis and MNP 5, 2=enable V.42 bis and MNP 5,
3=enable V.42 bis and MNP 5 (default).
+EB=
a
,
b
,
c
Select break handling (
b
and
c
are optional):
a
=0 — break is ignored.
b
=0 — transmitted V.42 L-SIGNAL will not indicate break signal length.
c
=0 — break is not delivered to DTE.
+EFCS=0
Select 16-bit FCS specified in V.42.
+ER:
a
Select error control protocol: NONE=error control not in use, LAPM=V.42 LAPM protocol, ALT=MNP.
+ER=
n
Error control reporting: 0=disable, 1=enable.
+ES=
a
,
b
,
c
Select error control and synchronous mode (
b
and
c
are optional).
a
is requested mode when modem is originator: 0=initiate call with direct mode, 1=initiate call with
normal mode, 2=initiate V.42 without detection phase, 3=initiate V.42 with detection phase (default),
4=initiate MNP, 6=initiate V.80 synchronous access mode when connection is completed.
b
specifies fallback mode when modem is originator: 0=LAPM, MNP, or normal mode error control
optional (default); 1=LAPM, MNP, or direct mode error control optional; 2=LAPM or MNP error control
required; 3=LAPM error control required; 4=MNP error control required.
c
specifies fallback mode when modem is answerer or specifies V.80 synchronous access mode:
1=error control disabled, use normal mode; 2=LAPM, MNP, or normal mode error control optional
(default); 3=LAPM, MNP, or direct mode error control optional; 4=LAPM or MNP error control
required; 5=LAPM error control required; 6=MNP error control required; 8=initiate V.80 synchronous
access mode when connection complete.
+ESR=0
Disable selective repeat option in V.42.
+ETBM=
a
,
b
,
c
Handle data remaining in modem buffers on call termination (
b
and
c
are optional):
a
=0 — disconnect occurs immediately and buffered transmit data is discarded.
b
=0 — disconnect occurs immediately and buffered receive data is discarded.
c
=0 — modem does not attempt to deliver buffered data and discards data.
FAX Class 1
+FAE=
n
Data/fax auto answer: 0=disable (default), 1=enable.
+FAR=
n
0=disable adaptive reception (default), 1=enable.
+FCL=
n
Set loss-of-carrier delay in units of 100 ms (
n
=0 to 255).
+FCLASS=
n
Set active service class: 0=data mode (default), 1=Fax Class 1, 1.0=Fax Class 1.0 mode, 8=voice
mode.
+FIT=
n
,
a
Set DTE inactivity timeout
n
seconds after which modem goes on-hook (
a
=0) or DCE goes on hook
(
a
=1).
+FLO=
a
Set flow control type: 0=XON/XOFF and RTS/CTS flow control turned off; 1=XON/XOFF flow control
in either direction; 2=RTS for flow control of modem by DTE, and CTS for flow control of DTE by
modem.