HP Scitex LX600 HP Designjet L65500 Printer and HP Scitex LX Printer Family - - Page 29
Tri-phase AC Power Cord
View all HP Scitex LX600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
The AC power cords (tri-phase and single-phase) have to be screwed to the bottom terminals of the switch. Add adequate ferrules on power cord cable terminations. In total there are 6 terminals to attach wires, and only 5 of them are to be used. They are labeled (from left to right): L1, L2, L3, (blank), L0 and N. Each wire must be securely attached to the terminals of the power switch. Label on Switch L1 L2 L3 Blank L0 N Wire Phase Phase Phase - Phase Neutral Power Cord Tri-phase Tri-phase Tri-phase - Single-phase Single-phase ENWW Tri-phase AC Power Cord 25
The AC power cords (tri-phase and single-phase) have to be screwed to the bottom terminals of the
switch. Add adequate ferrules on power cord cable terminations. In total there are 6 terminals to attach
wires, and only 5 of them are to be used. They are labeled (from left to right): L1, L2, L3, (blank), L0 and
N. Each wire must be securely attached to the terminals of the power switch.
Label on Switch
Wire
Power Cord
L1
Phase
Tri-phase
L2
Phase
Tri-phase
L3
Phase
Tri-phase
Blank
—
—
L0
Phase
Single-phase
N
Neutral
Single-phase
ENWW
Tri-phase AC Power Cord
25