Choose delta or star (Y) configuration

Page 33 highlights

Choose delta or star (Y) configuration Manpower 1 person Tools T10 and M15 screwdriver, M7 wrench Time 5 minutes There are two Delta/Star terminal blocks located on the printer that must be configured. Use the following table to make the configuration, and follow the procedures below to access the two terminal blocks. CAUTION: Both Delta/Star terminal blocks must use the same configuration. Delta configuration1 Star configuration2 1 Use the delta configuration for tri-phase power supply voltages from 200-220 V (between phases). 2 Use the star configuration for tri-phase power supply voltages from 380-415 V (between phases). Heating Module Configuration 1. Remove the six T10 screws securing the middle cover of the heating module and remove it. TIP: The heating module cover you must remove is marked with orange tape. ENWW Choose delta or star (Y) configuration 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

Choose delta or star (Y) configuration
Manpower
Tools
Time
1 person
T10 and M15 screwdriver, M7 wrench
5 minutes
There are two Delta/Star terminal blocks located on the printer that must be configured. Use the following
table to make the configuration, and follow the procedures below to access the two terminal blocks.
CAUTION:
Both Delta/Star terminal blocks must use the same configuration.
Delta configuration
1
Star configuration
2
1
Use the delta configuration for tri-phase power supply voltages from 200–220 V (between phases).
2
Use the star configuration for tri-phase power supply voltages from 380–415 V (between phases).
Heating Module Configuration
1.
Remove the six T10 screws securing the middle cover of the heating module and remove it.
TIP:
The heating module cover you must remove is marked with orange tape.
ENWW
Choose delta or star (Y) configuration
29