HP Scitex LX600 HP Designjet L65500 Printer and HP Scitex LX Printer Family - - Page 32

Install the fuses, Install the power jumpers, pump to work incorrectly.

Page 32 highlights

Install the fuses 1. Use the key to access the electrical cabinet. 2. Open the two fuse holder blocks. 3. Insert the six fuses (three per fuse block) into the fuse holder with the piston facing you. Printer Sites with high voltage supply (200- Sites with low voltage supply (100- 290V) 120) HP Designjet L65500/LX600 20 A 32 A HP Designjet LX800 25 A 1 Japan may have input frequencies of 50 Hz or 60 Hz 40 A 4. Close the fuse holder until you feel and hear a "click." The red square above the fuse holder should change color once all fuse holders have been inserted. Install the power jumpers 1. There are five power jumpers supplied. Select the appropriate power jumper according to the single-phase power at the installation site. Inserting the wrong power jumper will cause the vacuum pump to work incorrectly. 2. Insert the correct power jumper into the connector, located close to the transformer. 28 Chapter 6 Configure the electrical system ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

Install the fuses
1.
Use the key to access the electrical cabinet.
2.
Open the two fuse holder blocks.
3.
Insert the six fuses (three per fuse block) into the fuse holder with the piston facing you.
Printer
Sites with high voltage supply (200–
290V)
Sites with low voltage supply (100–
120)
HP Designjet L65500/LX600
20 A
32 A
HP Designjet LX800
25 A
40 A
1
Japan may have input frequencies of 50 Hz or 60 Hz
4.
Close the fuse holder until you feel and hear a “click.” The red square above the fuse holder should
change color once all fuse holders have been inserted.
Install the power jumpers
1.
There are five power jumpers supplied. Select the appropriate power jumper according to the
single-phase power at the installation site. Inserting the wrong power jumper will cause the vacuum
pump to work incorrectly.
2.
Insert the correct power jumper into the connector, located close to the transformer.
28
Chapter 6
Configure the electrical system
ENWW