Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 131

Connecting Duct, for M4 self-tapping screw, to the duct flange optional

Page 131 highlights

6-4. Connecting Duct 1. Specifications outlet duct (field supply) filter chamber with middle/ high-performance filter (field supply) canvas duct (field supply) 1-31/32 (50) outlet port (field supply) Intake grille with low-performance filter (field supply) AIR FLOW K - ø5/32" (ø4.1) holes For 13/64" (M5) self-tapping screw (1) Install the duct (field supply) to air intake port side. See the figure for the dimension of the installation hole. Use M5 self-tapping screws for installation. (Fig. 1-45) NOTE 1-31/32 (50) 9-27/32 (250) 5-29/32 (150) J H G H • To get clean air and to extend the service life of the air Type G H J K conditioner, an air filter must be installed in the air inch 35-7/16 (Pitch 5-29/32 × 6) 63/64 33/64 intake. For installation and cleaning the air filter, consult your dealer or service center. 26 mm 900 (Pitch 150 × 6) 25 13 18 36 inch 53-5/32 (Pitch 5-29/32 × 9) mm 1,350 (Pitch 150 × 9) 0 0 33/64 13 24 1 Fig. 1-45 (2) Install the duct (field supply) to air outlet port side. • Connection to the duct flange (supplied) See the figure for the dimension of the installation hole. Use M4 self-tapping screws for installation. E(fo-ør 1M/84" (søe3l)f-htaoplepsing screw) A = 5-29/32"(P150) x B D C 6-1/16 (154) 49/64 (19.4) 1-5/32 (29.4) unit: inch (mm) 29/32 (23) 1-1/16 (27) 5-33/64 (140) 7-21/64 (186) • Connection to the duct flange (optional) See the figure for the dimension of the installation hole. unit: inch (mm) Type A BC DE 26 inch 29-17/32 mm 750 5 53/64 31-3/16 16 21 792 36 inch 41-11/32 7 2-51/64 46-59/64 20 mm 1050 71 1192 pitch G [ H ø7-7/8 (ø F Type F GH 26 inch 11-7/16 10-15/64 2 mm 290 260 36 inch 12-13/32 11-7/16 mm 315 290 3   1-123

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297

1-123
1. Specifications
6-4. Connecting Duct
outlet duct (field supply)
outlet port (field supply)
AIR FLOW
filter chamber with middle/
high-performance filter
(field supply)
canvas duct
(field supply)
Intake grille with
low-performance
filter (field supply)
(1) Install the duct (field supply)
to air intake port side.
See the figure for the dimension of the installation hole.
Use M5 self-tapping screws for installation.
(Fig. 1-45)
NOTE
To get clean air and to extend the service life of the air
conditioner, an air filter must be installed in the air
intake.
For installation and cleaning the air filter, consult your
dealer or service center.
(2) Install the duct (field supply) to air outlet port side.
• Connection
to the duct flange (supplied)
See the figure for the dimension of the installation hole.
Use M4 self-tapping screws for installation.
49/64
(19.4)
1-5/32
(29.4)
6-1/16
(154)
A
B
C
D
= 5-29/32”(P150) x
1-1/16
(27)
7-21/64
(186)
5-33/64
(140)
29/32
(23)
E
-ø1/8” (ø3) holes
(for M4 self-tapping screw)
unit: inch (mm)
• Connection
to the duct flange (optional)
See the figure for the dimension of the installation hole.
F
G
H
ø7-7/8
unit: inch (mm)
pitch
H
K
G
H
J
- ø5/32” (ø4.1) holes
1-31/32
(50)
1-31/32
(50)
(250)
5-29/32
(150)
9-27/32
For 13/64” (M5) self-tapping screw
Type
G
H
J
K
26
inch
35-7/16 (Pitch 5-29/32 × 6)
63/64
33/64
18
mm
900 (Pitch 150 × 6)
25
13
36
inch
53-5/32 (Pitch 5-29/32 × 9)
0
33/64
24
mm
1,350 (Pitch 150 × 9)
0
13
Type
A
B
C
D
E
26
inch
29-17/32
5
53/64
31-3/16
16
mm
750
21
792
36
inch
41-11/32
7
2-51/64
46-59/64
20
mm
1050
71
1192
Type
F
G
H
26
inch
11-7/16
10-15/64
2
mm
290
260
36
inch
12-13/32
11-7/16
3
mm
315
290
Fig. 1-45
1