Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 180

Suspending the Indoor Unit, 57. Preparation Before Installation

Page 180 highlights

6-57. Preparation Before Installation (1) Remove the bracket (for suspending the indoor unit). Loose the M8 or 5/16" suspension bolts. Then remove the bracket. (Fig. 1-184) NOTE Loosen the M8 or 5/16" suspension bolts and expose the axis of bolts less than 5/16" (8 mm). Less than 5/16" (8 mm) 1. Specifications (4) Remove the center bracket. When wiring, remove the center bracket if necessary. When wiring is completed, reinstall the center bracket in its original position. Center bracket 6-58. Suspending the Indoor Unit Fig. 1-188 NOTE M4 or 5/32" screw for preventing bracket from M8 or 5/16" suspension bolts for suspending the indoor unit taking off Bracket Since the diagram is made of paper, it may shrink or stretch slightly because of high temperature or humidity. For this reason, before drilling the holes maintain the correct Fig. 1-184 dimensions between the markings. (2) Remove the air-intake grille before suspending the indoor unit. First, 1 remove 2 attachment screws fixed with the latches. Open the airintake grille and hold the claws of the hinges on both sides. Then (1) If the full-scale installation diagram is placed on the ceiling, the locations of each suspension bolt can be chosen. Take a pencil and mark the drill holes (Fig. 1-189). remove the air-intake grille and suspension lug located on the left and right side of the indoor unit. Ceiling Full-scale installation diagram Air-intake grille Screw 1 Latch 1 Slide 2 claws Air-intake grille Remove Fig. 1-185 Remove (3) Remove the side plate to the tubing side. Fig. 1-186 Rear & upper side tubing connection Right side tubing connection Remove 2 screws. Slide the side plate in the direction of the arrow and remove it. Do not remove the side plate. Remove Full-scale installation diagram Wall Fig. 1-189 (2) If the full-scale installation diagram is bent at right angle to the ceiling and wall, the locations of the inlet for indoor tubing and wiring are chosen and the locations of each suspension bolt can also be chosen. Take a pencil and mark the drill holes (Fig. 1-190). Ceiling Full-scale installation diagram Wall Full-scale installation diagram Fig. 1-190 NOTE The dimension when the indoor unit is placed tightly against the wall. When installing away from the wall, drainage gradient should be taken into consideration. (3) Drill holes at the 4 points indicated on the full-scale diagram. (4) Depending on the ceiling type: a) Insert suspension bolts (Fig. 1-191). or b) Use existing ceiling supports or construct a suitable support (Fig. 1-192). Hole-in-anchor Hole-in-plug Concrete Insert Ceiling tiles Ceiling support Screw Side plate Fig. 1-187 1-172 Suspension bolt (M10 or 3/8") (not supplied) Fig. 1-191 Fig. 1-192

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297

1-172
1. Specifications
6-57. Preparation Before Installation
(1)
Remove the bracket (for suspending the indoor unit).
Loose the M8 or 5/16” suspension bolts.
Then remove the bracket. (Fig. 1-184)
NOTE
Loosen the M8 or 5/16” suspension bolts and expose the
axis of bolts less than 5/16” (8 mm).
M4 or 5/32” screw for
preventing bracket from
taking off
M8 or 5/16” suspension bolts
for suspending the indoor unit
Bracket
Less than 5/16” (8 mm)
Fig. 1-184
(2)
Remove the air-intake grille before suspending the indoor unit. First,
remove 2 attachment screws fixed with the latches. Open the air-
intake grille and hold the claws of the hinges on both sides. Then
remove the air-intake grille and
suspension lug located on the left
and right side of the indoor unit.
1
1
2
Slide
Latch
claws
Screw
Air-intake grille
Fig. 1-185
Air-intake grille
Remove
Remove
Fig. 1-186
(3)
Remove the side plate to the tubing side.
Rear & upper side
tubing connection
Remove 2 screws.
Slide the side plate in the direction of
the arrow and remove it.
Right side tubing
connection
Do not remove the side plate.
Remove
Screw
Side plate
Fig. 1-187
(4)
Remove the center bracket.
When wiring, remove the center bracket if necessary. When
wiring is completed, reinstall the center bracket in its original
position.
Center bracket
Fig. 1-188
6-58. Suspending the Indoor Unit
NOTE
Since the diagram is made of paper, it may shrink or stretch
slightly because of high temperature or humidity.
For this reason, before drilling the holes maintain the correct
dimensions between the markings.
(1)
If the full-scale installation diagram is placed on the ceiling, the
locations of each suspension bolt can be chosen.
Take a pencil and mark the drill holes (Fig. 1-189).
Full-scale installation diagram
Ceiling
Wall
Full-scale installation diagram
Fig. 1-189
(2)
If the full-scale installation diagram is bent at right angle to the
ceiling and wall, the locations of the inlet for indoor tubing and
wiring are chosen and the locations of each suspension bolt
can also be chosen.
Take a pencil and mark the drill holes (Fig. 1-190).
Full-scale installation diagram
Ceiling
Wall
Full-scale installation diagram
Fig. 1-190
NOTE
The dimension when the indoor unit is placed tightly
against the wall.
When installing away from the wall, drainage gradient
should be taken into consideration.
(3)
Drill holes at the 4 points indicated on the full-scale diagram.
(4)
Depending on the ceiling type:
a) Insert suspension bolts (Fig. 1-191).
or
b) Use existing ceiling supports or construct a suitable
support (Fig. 1-192).
Hole-in-anchor
Hole-in-plug
Suspension bolt (M10 or 3/8”)
(not supplied)
Insert
Ceiling tiles
Ceiling support
Concrete
Fig. 1-191
Fig. 1-192
1