To unmount indoor unit (1) Remove the screw cover on the bottom surface. (Fig. 1-176) (2) Fasten the frame to the rear panel using the 2 supplied tapping screws 5/32 × 13/32" (4 × 10 mm). (Fig. 1-176) (3) Press the 2 marks on the lower part of the indoor unit and unlatch the tabs. Then lift the indoor unit and unmount. (Fig. 1-177) NOTE Under normal conditions, the installation design calls for a less than 2 mm gap between the air conditioner unit and the wall. Confirm that the gap is appropriate (less than 5/64" (2 mm)). 6-54. Drain Hose a) The drain hose should be slanted downward to the outdoors. (Fig. 1-178) b) Never form a trap in the course of the hose. c) If the drain hose will run in the room, insulate the hose with insulation* so that chilled condensation will not damage furniture or floors. (Fig. 1-179) *Foamed polyethylene or its equivalent is recommended. WARNING Do not supply power to the unit or operate it until all tubing and wiring to the outside unit are completed. Risk of Electric Shock Screw cover 1. Specifications Screw Fig. 1-176 1 Push Fig. 1-177 Indoor unit Slant Drain hose Fig. 1-178 Condensation Insulation material (Locally purchased) must be used. 1-169 Fig. 1-179