Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 267
Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit Alarm History
View all Panasonic 26PEK2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 267 highlights
5. Outdoor unit maintenance remote control 5-5. Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit Alarm History * Displays outdoor unit alarms only. Does not display indoor unit alarms. * Check the indoor unit alarm histories separately using the indoor unit remote controllers or other control device. (1) Press and hold the button and button simultaneously for 4 seconds or longer to change to outdoor unit alarm history mode. During the alarm history display, "Service Check" is lit. The display and operations are the same as the monitoring of the alarm device (3) history that is performed using the unit remote controller. However, the outdoor unit address appears instead of the unit No. (5) (1) (4) (2) (2) Press the button and select the outdoor unit for alarm history monitoring. (3) Use the temperature setting and buttons to select the item code for the alarm history. The display shows the address of the selected outdoor unit, the item code, and the alarm history (alarm data). The outdoor unit address is displayed as system XX-YY. System XX = Outdoor unit system address YY = Outdoor unit sub-bus address The item code is displayed as 01- 08. 01 indicates the most recent alarm. The alarm history is indicated by the alarm code. (If there have been no alarm codes, " " is displayed.) (4) To clear the alarm history, press the button. (The outdoor unit alarm history will be cleared.) (5) To end, press the button. The display returns to the normal remote controller display. 5-6. Setting Modes: Setting the Outdoor Unit EEPROM Setting mode 1 A Display of first 3 digits (1) Press and hold the button and button simultaneously for 4 seconds or longer. (2) Use the temperature setting and buttons to change the item code. The item codes and setting data are shown in the table on the next page. (5) (3) Use the timer time and buttons to change the setting data. (2) To confirm the changed setting data, press the button. (At this time, "Setting" stops blinking and remains lit.) (1) (3) (4) During this mode, "Setting" is displayed, blinking. The outdoor unit address display section displays "ALL," the item code and number (DN B Display of last 3 digits value in the table), and the setting data (6 digits). (The setting data is displayed in 6 digits. The display changes between the first 3 digits (Fig. A ) and the last 3 digits (Fig. B ). 5 When the first 3 digits are displayed, the top point of the colon is lit.) (5) To end the setting mode, press the button. A and B are displayed alternately. (Example shows display of 000 001.) 5-7