Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 185
Room Temperature Sensor Setting, 3. Address Switches, 4. Setting the Model Code, Fig. 1-209
View all Panasonic 26PEK2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 185 highlights
7-2. Room Temperature Sensor Setting 1. Specifications The room temperature sensors are built into the indoor unit and the wireless remote controller. Either of these room temperature sensors can operate. The system is shipped from the factory set to the indoor unit sensor. To switch to the remote control sensor, press the sensor switching button located inside the remote control cover and check that A/C SENSOR on the LCD display panel goes out. NOTE If the sensor switch is set to the remote controller side, but no room temperature data is sent to the main unit for 10 minutes, the sensor is automatically switched to the indoor unit side. As much as possible, install the remote controller facing the unit. 7-3. Address Switches Sensor button Fig. 1-209 If you are installing more than 1 indoor unit (up to 6) in the same room, it is necessary for you to assign each unit its own address so they each can be operated by their remote controller. 1 Up to 6 indoor units can be controlled separately through the address switches. The operating control has the reception address switch and the remote controller has the transmission address switch. This function is utilized by matching the transmission and reception address switches. Remote control ADR address display ADR ADR Address switch * Any address 123 123 positions switch position available 456 456 ADR 123 456 7-4. Setting the Model Code Flap display selector switch Make the slide switch settings in the battery compartment box of the remote controller depending on the type of indoor unit in which the wireless receiving unit is used. Operation mode switch In this Single Split System Air Conditioner set the switch to "A". * The switch is factory set to "S" / "A". * Always press the reset button after switching the setting. SKN AHC 2 Operation mode switch 1 Flap display selector switch Fig. 1-210 1 SKN Type U1, T1 SKN Type K1 AHC AHC 2 Heat pump with Heat pump without Auto mode Auto mode SKN Type F1, F2 AHC Cooling only 1-177