Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 42
MODEL No, S-26PK1U6, Source, 208 VAC / 1 phase / 60Hz, Remote, controller, Optional / Supplied
View all Panasonic 26PEK2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
1-2. Major Component Specifications (A) Indoor Unit MODEL No. Source Remote controller (Optional / Supplied) Controller P. C. B Ass'y Control circuit fuse Fan Number ... Dia. and length in. (mm) Fan motor Model Source No. of pole ... r.p.m. (230 V, High) rpm Nominal output W Coil resistance Ω (Ambient temperature 68 °F) 1 Safety device Operating temperature Open °F Close °F Run capacitor VAC, µF Heat exchanger Coil Rows ... Fins per inch Face area ft.2 (m2) 1. Specifications S-26PK1U6 230 - 208 VAC / 1 phase / 60Hz Wired / Wireless (See Unit Specifications) CB-KR254GXH56A 250 V, 5 A Cross-flow 1 ... O.D. 4-1/3 (110), L39 (990) KFT4Q - 31A6P - C 230 - 208 V / 1 phase / 60 Hz 4 ... 1,224 28.8 BRW - WHT : 260.7 , ORG - YEL : 23.76 WHT - VLT : 42.62 , YEL - PNK : 115.9 VLT - ORG : 30.36 , 266 ± 14.4 174.2 ± 26 440 V , 1.8 µF Aluminum plate fin / Copper tube 2 ... 24.1 2.57 (0.24) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 1-34