Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 195
Fig. 1-230, Fit securely into the ceiling material at s
View all Panasonic 26PEK2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 195 highlights
When using the signal receiving unit on a wall with the front exposed, choose a wall surface that the signal receiving unit can be mounted on. (1) Insert a flathead screwdriver into the slot on the lower side of the signal receiving unit and pry off the back case. 1. Specifications Run the remote con cable through a notch in the upper case. Clamp (Supplied) About 3/32"-1/8" (2) The wire routing at the signal receiving unit comes out of the upper case (thin portion at upper center) so use nippers or a similar tool to cut out a notch beforehand large enough for the remote control cable (option) to Fig. 1-230 Connector Remote control cord (Option) Fig. 1-231 pass through as shown in Fig. 1-230. (3) Remove the wire, which is connected prior to shipping, Remote control cord (Option) Signal receiving unit from the connector. Clamp (4) Connect the remote control cable (option) to the signal receiving unit connector as shown in Fig. 1-231 after the clamp (supplied) with the unit is installed. ALL• RTPECCSUBT:CRSHUUNKB. (5) After arranging the wiring on the printed circuit board RNCOURM: MALAIN 123 as shown in Fig. 1-232 so that it is contained within the ADR 456 signal receiving unit, attach the back case. At this time, arrange so that the head of the clamp faces the side. 1 (6) Remove the cover plate and install the signal receiving unit using the 2 wood screws. Fig. 1-232 Wood screws (2) (7) Fasten to the wall using the cord clip (supplied). (8) Reinstall the cover plate. Fig. 1-233 To use the signal receiving unit while mounted on the A ceiling, install by using the carrier for ceiling installation supplied with the unit. (1) Remove the cover plate by inserting a flathead screwdriver into the notch in the lower section and prying it off. (2) Cut out a section (3-3/4"×2-1/32") on the ceiling using the paper pattern (supplied) as a guide. (3) Run the wire through the mounting carrier and insert into the installation hole as shown in Fig. 1-234. Fig. 1-234 B (4) Fit securely into the ceiling material at sections (A) and (B) as shown in Fig. 1-235. (5) Connect the wire (2-wire core) from the signal receiving unit with the wire from the indoor unit. (See section on how to wire the receiving unit.) as shown in Fig. 1-235. Fig. 1-235 (6) Use the supplied spacers to adjust for a thickness several inches more than the ceiling material and lightly fasten the receiving unit in place with the small screws (M4×1-9/16", 2 pcs.) supplied with the unit. (7) Tighten the machine screws after fitting sections (A) and (B) into the openings, in the gap between the signal receiving unit and ceiling surface as in Fig. 1-236. Do not apply strong force when tightening the screws. Excessive force might warp or damage the cover. When finished, the signal receiving unit should still be able to move slightly when pressed as shown in Fig. 1-236. Fig. 1-236 (8) Reinstall the cover plate. 1-187