MODEL No, S-36PT1U6, Source, 208 VAC / 1 phase / 60Hz, Remote, controller, Supplied / Optional,
View all Panasonic 26PEK2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
1-2. Major Component Specifications (A) Indoor Unit MODEL No. Source Remote controller (Supplied / Optional) Controller P. C. B Ass'y Control circuit fuse Fan (Number ... diameter) Fan motor Model Source No. of pole ... r.p.m. (230 V, High) Nominal output Coil resistance (Ambient temperature 68 °F) in. (mm) rpm W Ω 1 Safety device Operating temperature Open °F Close °F Run capacitor VAC, µF Heat exchanger Coil Rows ... Fins per inch Face area ft.2 (m2) Auto louver motor Model No. Auto louver motor ... Rated V, W, rpm Coil resistance (Ambient temperature 77 °F) Ω 1. Specifications S-36PT1U6 230 - 208 VAC / 1 phase / 60Hz Wired / Wireless (See Unit Specification) CR - TH2672 250 V, 5 A Centrifugal (4 ... 5-29/32(150)) KFG4X - 101C6P 230 - 208 V / 1 phase / 60 Hz 4 ... 1,040 100 BRW - WHT : 61.05 , ORG - YEL : 13.23 WHT - VLT : 9.955 , YEL - BLK : 19.25 VLT - ORG : 9.576 , BLK - PNK : 10.81 266 ± 14.4 174.2 ± 27 440 V , 5 µF Aluminum plate fin / Copper tube 3 ... 14.9 3.51 (0.326) MT8 - 3C 240 VAC , 3 W , 3 rpm 16,430 Ω ± 8 % DATA SUBJECT TO CHANGE WITHOUT NOTICE. 1-36