Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 64
Dimensional Data, Air intake port side, Air outlet duct side
View all Panasonic 26PEK2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
1-4. Dimensional Data Indoor Unit : Concealed Duct (Type F2) Air intake port side 1. Specifications Unit: inch (mm) g 6-49/64 (172) e 11-1/32 (280) 1 h 1-5/16 (33.4) D 2-1/8 (54) A(Suspension bolt pitch) B F-ø1/8 (ø3)holes 25-3/64 (636) Inspection access 23-5/8 × 23-5/8 (600 × 600 mm) (Field supply) 11-7/16 (290) 10-3/64 (255) f j i c d 1-1/32 (26.1) 11-13/16 (300) 27-9/16 10-5/64 (700) (256) 2-9/16 (65) C E(Flange O.D.) Air outlet duct side 5-29/32 D (150) 1-5/16 (33.4) 6-1/16 (154) 1-3/16 (30) 4-29/64 (113) a 29/32 (23) b 3-35/64 (90) 2-3/4 (70) 29/32 (23) 5-33/64 (140) 7-21/64 1-1/16 (186) (27) a) Refrigerant tubing joint (liquid tube) b) Refrigerant tubing joint (gas tube) c) Upper drain port VP25 (O.D. 1-17/64" (O.D. 32 mm)) 7-7/8" (200 mm) flexible hose supplied d) Bottom drain port VP25 (O.D. 1-17/64" (O.D. 32 mm)) e) Suspension lug (4 - 15/32" × 1-3/16" (4 - 12 × 30 mm)) f ) Inter-unit control wiring port g) Fresh air intake port (ø5-29/32" (ø150 mm)) h) Flange for flexible air outlet duct i ) Electrical component box j ) Power supply wiring port Type 26 36 A inch 42-1/64 mm 1,067 inch 57-3/4 mm 1,467 B 39-3/8 1,000 55-1/8 1,400 C D E F 29-17/32 (Pitch 5-29/32 × 5) 53/64 31-3/16 750 (Pitch 150 × 5) 21 792 16 41-11/32 (Pitch 5-29/32 × 7) 2-51/64 46-59/64 1,050 (Pitch 150 × 7) 20 71 1,192 1-56