Panasonic 26PEK2U6 26PEK2U6 Service Manual - Page 175
Mounting, 52. Right-side tubing
View all Panasonic 26PEK2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 175 highlights
6-51. Mounting (1) To install the indoor unit, mount the indoor unit onto the 3 tabs on the upper part of the rear plate. (2) Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely fasten to the 2 tabs on the lower part of the rear plate. (Fig. 1-165) NOTE For tubing, choose either the right or left tubing direction and follow the steps below. Also, extend the support on the back of the indoor unit as a stand to make your work easier. (Fig. 1-166) 6-52. Right-side tubing (1) Shape the refrigerant tubing so that it can easily go into the wall hole. (Fig. 1-167) (2) Push the wiring, refrigerant tubing, and drain hose through the hole in the wall. Adjust the indoor unit so it is securely seated on the rear panel. (Fig. 1-168) (3) Carefully bend the tubing (if necessary) to run along the wall in the direction of the outdoor unit and then tape as far as the fittings. The drain hose should come straight down the wall to a point where water runoff won't stain the wall. (4) Connect the refrigerant tubing to the outdoor unit. (After performing a leak test on the connecting part, insulate it with the tubing insulation. (Fig. 1-169)). (5) Assemble the refrigerant tubing, drain hose, and conduit (including inter-unit wiring) as shown in Fig. 1-170. Refrigerant tubing Fig. 1-169 Flare insulation Conduit Drain hose Inter-unit wiring Fig. 1-170 1. Specifications Push Fig. 1-165 Rear panel Rear panel Cover 1 Fig. 1-166 Refrigerant tubing Inter-unit wiring Drain hose Fig. 1-167 1-167 Fig. 1-168