Adaptec 1966600 User Guide - Page 16

Cooling Fan Module, AC Power Cord, Connectors, Provides AC Power, to Power Supply 1

Page 16 highlights

DuraStor 6220SS/7220SS Installation and User's Guide Figure 2-7 shows the AC power cord connectors on the back of the chassis. The security bales hold the power cords in place and prevent accidental disconnections. Provides AC Power to Power Supply 1 Provides AC Power to Power Supply 2 AC Power Cord Connectors Figure 2-7. DuraStor RAID Appliance Power Cord Connector Location Cooling Fan Module The cooling system of the DuraStor RAID appliance consists of three high-performance cooling fans contained in a module that fits into a bay on the back of the appliance. See Figure 2-8. The module is easily accessible and hot-swappable. Figure 2-8. DuraStor RAID Appliance Cooling Fan Module If the appliance temperature exceeds the established threshold of 60 °C (140 °F), the Fault LED begins to flash. (The controller 2-6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

2-6
DuraStor 6220SS/7220SS Installation and User’s Guide
Figure 2-7
shows the AC power cord connectors on the back of the
chassis. The security bales hold the power cords in place and
prevent accidental disconnections.
Figure 2-7.
DuraStor RAID Appliance Power Cord Connector Location
Cooling Fan Module
The cooling system of the DuraStor RAID appliance consists of
three high-performance cooling fans contained in a module that fits
into a bay on the back of the appliance. See
Figure 2-8
. The module
is easily accessible and hot-swappable.
Figure 2-8.
DuraStor RAID Appliance Cooling Fan Module
If the appliance temperature exceeds the established threshold of
60 °C (140 °F), the Fault LED begins to flash. (The controller
AC Power Cord
Connectors
Provides AC Power
to Power Supply 1
Provides AC Power
to Power Supply 2