Dell PowerConnect Brocade M6505 Brocade 7.1.0 Fabric Watch Administrator's Gui - Page 34
In-between buffer values, Threshold triggers
View all Dell PowerConnect Brocade M6505 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
2 Threshold triggers In-between buffer values The below high threshold is the term used to configure "in between" buffer values, as shown in Figure 1. In this example, the high threshold value is 5 and the buffer value is 1. Therefore, the "in-between" boundary value is 4. Enter the portThConfig command using the following parameters. portthconfig --set port -area crc -highth -value 5 -trigger below -action raslog -buffer 1 Above high threshold Above action = 5 HIGH THRESHOLD, BUFFER = 1 Below high threshold Low action Above low threshold In-between Above action LOW THRESHOLD, BUFFER=1 Below low threshold Low action FIGURE 1 In-between buffer values Threshold triggers This section describes how Fabric Watch compares a fabric element's data value against a threshold value to determine whether or not to trigger an event. It describes how a specified buffer zone affects event triggering. For Fabric Watch to monitor data values for one of the following conditions, the alarm setting must be set to a nonzero value. 14 Fabric Watch Administrator's Guide 53-1002752-01