Dell PowerConnect Brocade M6505 Brocade 7.1.0 Fabric Watch Administrator's Gui - Page 95

System Monitoring, In this Environment monitoring, Environment class area

Page 95 highlights

System Monitoring Chapter 8 In this chapter •Environment monitoring 75 •Resource class settings 77 •System monitoring using the sysMonitor command 78 •Recommended environment and resource monitoring settings 81 •Switch monitoring 81 •FRU monitoring 84 Environment monitoring The Environment class provides information about the internal temperature of the switch. You can configure the Environment class using the sysMonitor command. Environment class area Table 23 lists and describes the Temperature area in the Environment class. TABLE 23 Environment class area Area Description Temperature Refers to the ambient temperature inside the switch, in degrees Celsius. Temperature sensors monitor the switch in case the temperature rises to levels at which damage to the switch might occur. NOTE Event Manager (EM) now manages fan monitoring; the switch status is calculated based on fan status reported by EM. You can use the fanShow command to view the fan status. Fabric Watch Administrator's Guide 75 53-1002752-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Fabric Watch Administrator’s Guide
75
53-1002752-01
Chapter
8
System Monitoring
In this chapter
Environment monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
75
Resource class settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
77
System monitoring using the sysMonitor command. . . . . . . . . . . . . . . . . . .
78
Recommended environment and resource monitoring settings . . . . . . . . .
81
Switch monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
81
FRU monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
84
Environment monitoring
The Environment class provides information about the internal temperature of the switch. You can
configure the Environment class using the
sysMonitor
command.
Environment class area
Table 23
lists and describes the Temperature area in the Environment class.
NOTE
Event Manager (EM) now manages fan monitoring; the switch status is calculated based on fan
status reported by EM. You can use the
fanShow
command to view the fan status.
TABLE 23
Environment class area
Area
Description
Temperature
Refers to the ambient temperature inside the switch, in degrees Celsius. Temperature sensors
monitor the switch in case the temperature rises to levels at which damage to the switch might
occur.