Dell PowerConnect Brocade M6505 Brocade 7.1.0 Fabric Watch Administrator's Gui - Page 64
SFP monitoring default settings, traps. If other Port class issues are reported
View all Dell PowerConnect Brocade M6505 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
6 SFP monitoring guidelines and default settings SFP monitoring default settings The SFP default settings are shown in Table 8. The default alarm configuration (log all alarms only to the error log) is sufficient. It is recommended that you do not allow alerts to go out as SNMP traps. If other Port class issues are reported, review the error log for any supporting data for SFP issues. TABLE 8 Area SFP class default settings Description Default threshold settings Default alarm settings Threshold state Current Receive power (RXP) Voltage Temperature Transmit power (TXP) Power on hours Monitors SFP current Unit: mA Time Base: none Low: 0 High: 50 Buffer: 1 Monitors receive power in µWatts Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Monitors SFP electrical force in volts Unit: mV Time Base: none Low: 2970 High: 3630 Buffer: 10 Monitors SFP temperature Unit: Degrees C Time Base: none Low: -10 High: 85 Buffer: 3 Monitors transmit power in µWatts Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Monitors the number of hours the 16 Gbps SFP is powered. Unit: Changes Time Base: none Low: 0 High: 0 Buffer: 0 Below: 1 Above: 1 Below: 1 Above: 1 Below: 1 Above: 1 Below: 1 Above: 1 Below: 1 Above: 1 Below: 0 Above: 0 Out_of_range Out_of_range Out_of_range Out_of_range Out_of_range Out_of_range Out_of_range Out_of_range Out_of_range Out_of_range Informative Informative 44 Fabric Watch Administrator's Guide 53-1002752-01