HP Integrity rx2800 HP Smart Update Manager User Guide - Page 72

Defined groups: Management Servers-Three servers Management Server1, Management

Page 72 highlights

o ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.90 (BP000323.xml) o ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.80 (BP000315.xml) • Firmware: o System ROM o Smart Array controller o Hard drives o iLO • Software-later version of: o HP Insight Diagnostics Online Edition for Windows Server™ 2003 (cp008097.exe) o HP Systems Management Homepage for Windows® (cp008257.exe) • HP Smart Update Manager o Defined groups: Management Servers-Three servers (Management Server1, Management Server2, Management Server3) Example 1: This command-line input deploys the latest PSP and firmware components: hpsum /use_latest /allow_non_bundle_components /silent Results: All software components from the 7.90 PSP and firmware components, which HP SUM determined are required to be installed, were installed. Example 2: Either of the following command-line inputs can deploy the previous version of the PSP only and force all the components to be installed: • hpsum /f:bundle /softwareonly BP000315.xml • hpsum /b BP000315.xml /f:bundle /softwareonly Results: All software components from the 7.80 PSP, which HP SUM determined are required to be installed, were installed. No firmware was installed. Example 3: This command-line input deploys firmware: hpsum /romonly Results: All firmware components, which are required to be installed, were installed. No software was installed. Example 4: Either of the following command-line inputs can deploy two software components: • hpsum /f:software cp008097.exe cp008257.exe • hpsum /c cp008097.exe /c cp008257.exe /f:software Results: The two components were installed. No firmware or other software was installed. Example 5: Either of the following command-line inputs can deploy the latest PSP, later versions of components in the bundle, and firmware to three remote hosts and force all components to be installed: Scripted deployment 72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

Scripted deployment 72
o
ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.90 (
BP000323.xml
)
o
ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.80 (
BP000315.xml
)
Firmware:
o
System ROM
o
Smart Array controller
o
Hard drives
o
iLO
Software—later version of:
o
HP Insight Diagnostics Online Edition for Windows Server™ 2003 (
cp008097.exe
)
o
HP Systems Management Homepage for Windows® (
cp008257.exe
)
HP Smart Update Manager
o
Defined groups: Management Servers—Three servers (Management Server1, Management
Server2, Management Server3)
Example 1:
This command-line input deploys the latest PSP and firmware components:
hpsum /use_latest /allow_non_bundle_components /silent
Results: All software components from the 7.90 PSP and firmware components, which HP SUM
determined are required to be installed, were installed.
Example 2:
Either of the following command-line inputs can deploy the previous version of the PSP only and force all
the components to be installed:
hpsum /f:bundle /softwareonly BP000315.xml
hpsum /b BP000315.xml /f:bundle /softwareonly
Results: All software components from the 7.80 PSP, which HP SUM determined are required to be
installed, were installed. No firmware was installed.
Example 3:
This command-line input deploys firmware:
hpsum /romonly
Results: All firmware components, which are required to be installed, were installed. No software was
installed.
Example 4:
Either of the following command-line inputs can deploy two software components:
hpsum /f:software cp008097.exe cp008257.exe
hpsum /c cp008097.exe /c cp008257.exe /f:software
Results: The two components were installed. No firmware or other software was installed.
Example 5:
Either of the following command-line inputs can deploy the latest PSP, later versions of components in the
bundle, and firmware to three remote hosts and force all components to be installed: