HP LH4r Installation and configuration of the HP NetRAID, NetRAID-1 and NetRAI - Page 103

Run View/Add Configuration option of Configuration

Page 103 highlights

Chapter 8 Upgrading to an HP NetRAID-3Si Adapter 2. Install the new HP NetRAID-3Si adapter, as described in Step D of Chapter 5. Be sure to plug in the Battery Backup Unit first. 3. Connect all SCSI cables to the HP NetRAID-3Si, as described in Step E of Chapter 5. 4. Replace the HP NetServer cover, plug in the power cord, and turn on power to the HP NetServer. 5. After you see the flashing message "Firmware Initializing," you will see this message: Configuration of NVRAM and drives mismatch for Host Adapter X Run View/Add Configuration option of Configuration Utility Press any key to enter the Configuration Utility. This message tells you that the configuration information stored in the drives (the correct configuration) does not match the configuration information stored in NVRAM on the newly installed HP NetRAID adapter. NOTE If you have more than one HP NetRAID Series adapter installed, the message tells you which adapter number has the mismatch. Be sure to note which adapter needs to be reconfigured. 6. Press any key and the HP NetRAID Express Tools utility starts automatically. You see the Tools Management menu. 7. If you have more than one HP NetRAID Series adapter installed, do the following to select the adapter you have just installed: a. Choose Select Adapter from the Tools Management menu. b. Choose the adapter with the mismatched configuration. 8. Choose Configure from the Tools Management menu. 9. Choose View/Add/Delete from the Configure menu. 10. Choose View Disk Configuration from the View/Add/Delete menu. 11. After scanning has finished, press ESC. 95

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177

Chapter 8
Upgrading to an HP NetRAID-3Si Adapter
95
2.
Install the new HP NetRAID-3Si adapter, as described in Step D of
Chapter 5. Be sure to plug in the Battery Backup Unit first.
3.
Connect all SCSI cables to the HP NetRAID-3Si, as described in Step E of
Chapter 5.
4.
Replace the HP NetServer cover, plug in the power cord, and turn on
power to the HP NetServer.
5.
After you see the flashing message "
Firmware Initializing
," you
will see this message:
Configuration of NVRAM and drives mismatch for
Host Adapter
X
Run View/Add Configuration option of Configuration
Utility
Press any key to enter the Configuration Utility.
This message tells you that the configuration information stored in the
drives (the correct configuration) does not match the configuration
information stored in NVRAM on the newly installed HP NetRAID
adapter.
NOTE
If you have more than one HP NetRAID Series adapter
installed, the message tells you which adapter number has the
mismatch. Be sure to note which adapter needs to be
reconfigured.
6.
Press any key and the HP NetRAID Express Tools utility starts
automatically. You see the Tools Management menu.
7.
If you have more than one HP NetRAID Series adapter installed, do the
following to select the adapter you have just installed:
a. Choose
Select Adapter
from the Tools Management menu.
b.
Choose the adapter with the mismatched configuration.
8.
Choose
Configure
from the Tools Management menu.
9.
Choose
View/Add/Delete
from the Configure menu.
10.
Choose
View Disk Configuration
from the View/Add/Delete menu.
11.
After scanning has finished, press ESC.