HP LH4r Installation and configuration of the HP NetRAID, NetRAID-1 and NetRAI - Page 57

Install the Adapter

Page 57 highlights

Chapter 5 Installation and Configuration CAUTION Follow the procedures in your system's road map or in Information Assistant to successfully remove and replace the power supplies. Failure to follow these procedures may result in breaking the power management board. 5. To remove an existing adapter, disconnect its SCSI cables first. Install the Adapter CAUTION Do not allow the adapter to contact any part of the HP NetServer other than the PCI slot during installation. Do not allow the Battery Backup Unit (on HP NetRAID and HP NetRAID-3Si adapters) to contact any part of the HP NetServer during installation. Any such contact could cause a short in the battery pack and may damage other electrical components. To install the adapter: 1. Refer to Worksheet A that you filled out while reading Chapter 4 for the slot selected for the adapter. If the adapter is already installed, verify that it is in the correct slot. 2. If there is a slot cover on the PCI slot, remove it. 3. Install the adapter by following the installation instructions for installing PCI boards in your host system manual and on the chassis labels. Align the adapter card bus connector into the slot. Ensure that it does not physically interfere with adjacent cards. Press the card gently but firmly into the slot to seat it properly. The bottom edge of the card should be flush with the slot. Secure the adapter to the system chassis with a mounting screw. CAUTION The adapter is sensitive to static electricity and can easily be damaged by improper handling. Using a grounding strap is recommended. Before you remove the adapter from the bag, touch a grounded, unpainted metal surface on the system to discharge static electricity. 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177

Chapter 5
Installation and Configuration
49
CAUTION
Follow the procedures in your system's road map or in
Information Assistant to successfully remove and replace the
power supplies. Failure to follow these procedures may result
in breaking the power management board.
5.
To remove an existing adapter, disconnect its SCSI cables first.
Install the Adapter
CAUTION
Do not allow the adapter to contact any part of the
HP NetServer other than the PCI slot during installation.
Do not allow the Battery Backup Unit (on HP NetRAID and
HP NetRAID-3Si adapters) to contact any part of the
HP NetServer during installation. Any such contact could
cause a short in the battery pack and may damage other
electrical components.
To install the adapter:
1.
Refer to Worksheet A that you filled out while reading Chapter 4 for the
slot selected for the adapter. If the adapter is already installed, verify that
it is in the correct slot.
2.
If there is a slot cover on the PCI slot, remove it.
3.
Install the adapter by following the installation instructions for installing
PCI boards in your host system manual and on the chassis labels. Align
the adapter card bus connector into the slot. Ensure that it does not
physically interfere with adjacent cards. Press the card gently but firmly
into the slot to seat it properly. The bottom edge of the card should be
flush with the slot. Secure the adapter to the system chassis with a
mounting screw.
CAUTION
The adapter is sensitive to static electricity and can easily be
damaged by improper handling. Using a grounding strap is
recommended.
Before you remove the adapter from the bag, touch a
grounded, unpainted metal surface on the system to discharge
static electricity.