HP LH4r Installation and configuration of the HP NetRAID, NetRAID-1 and NetRAI - Page 130
Other BIOS Error Messages
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Chapter 11 Troubleshooting Following SCSI ID's are not Responding Channel-x:a.b.c Problem: On the channel listed (x), the physical drives with the SCSI IDs listed (a, b, c, and so on) are not responding. Suggested solution: Verify that the physical drives are connected and powered on. Other BIOS Error Messages Warning: Battery voltage Low Problem: The voltage of the battery backing the cache memory is low. Suggested solution: Fast charge the battery. This occurs automatically when the system is on. Battery temperature out of range Problem: The temperature of the battery backing the cache memory is too low or too high. Suggested solution: • If the battery is too cold, allow it to warm up first. The battery will not fast charge if it is too cold. • If the battery is too hot, check the system for overheating or fan failure. The battery will not fast charge if it is too hot. Battery life Low Problem: The battery backing the cache memory is approaching its predicted end of life. Suggested solution: Replace the battery backup module. Error: Following SCSI Disk not found and No Empty Slot Available for mapping it Problem: The physical disk roaming feature failed to find the physical drive with the listed SCSI ID, and no slot is available in which to map the physical drive. The controller cannot resolve the physical drives into a current configuration. Suggested solution: Reconfigure the array because the adapter cannot resolve the physical drives into the current configuration. 122