HP ProLiant DL280 Configuring Arrays on HP Smart Array Controllers Reference G - Page 48

Hiding warning prompts, Keyword abbreviations, Example command, Keyword, Abbreviation in ACU, ACU CLI

Page 48 highlights

8 16 (current value) 32 64 128 (default) 256 To determine which parameters can be queried, use the help feature of the CLI ("The help command" on page 51). Hiding warning prompts When you enter a command for an operation that can potentially destroy user data, the CLI displays a warning and prompts you for input (a y or an n) before continuing the operation. This situation is undesirable when running batch file scripts. To prevent warning prompts from being displayed, use the term forced as a parameter. Example command: ctrl ch="Lab4" ld 1 delete forced Under VMware ESXi 5.0, the forced flag is required for any command that has the option for a forced flag. If the forced parameter is not used, the system generates an error message notifying the user that the command could not be completed without this flag. Keyword abbreviations Several commonly used keywords in the ACU CLI have acceptable abbreviations, as shown in the following table. For a complete list of abbreviations, enter help shorthand in the ACU CLI. Keyword adapterid allunassigned arrayaccelerator cacheratio chassisname* chassisserialnumber chassisslot configurationmode connectionname controller ctrlpath degradedperformancemode drivetype drivewritecache elevatorsort enclosure exitonerror expandpriority inconsistencyrepairpolicy Abbreviation in ACU Keyword CLI ai nobatterywritecache all numberparitygroups aa parallelscsi cr physicaldrive ch* postprompttimeout csn preferredpathmode chs queuedepth cm raid1writebuffering cn rebuildpriority ctrl redundantcontroller cp serialnumber dpo spareactivationmode dt ssdphysicaldrive dwc stripesize es surfaceanalysiseventnotify enc surfacescandelay eoe surfacescanmode ep sufacescanpriority irp surfacescanschedule Abbreviation in ACU CLI nbwc npg ps pd ppto ppm qd r1wb rp rc sn sam ssdpd ss saen ssd ssm sp sss HP Array Configuration Utility 48

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

HP Array Configuration Utility
48
8
16 (current value)
32
64
128 (default)
256
To determine which parameters can be queried, use the help feature of the CLI ("
The help command
" on
page
51
).
Hiding warning prompts
When you enter a command for an operation that can potentially destroy user data, the CLI displays a
warning and prompts you for input (a
y
or an
n
) before continuing the operation. This situation is undesirable
when running batch file scripts. To prevent warning prompts from being displayed, use the term
forced
as
a parameter.
Example command:
ctrl ch="Lab4" ld 1 delete forced
Under VMware ESXi 5.0, the forced flag is required for any command that has the option for a forced flag.
If the
forced
parameter is not used, the system generates an error message notifying the user that the
command could not be completed without this flag.
Keyword abbreviations
Several commonly used keywords in the ACU CLI have acceptable abbreviations, as shown in the following
table. For a complete list of abbreviations, enter
help shorthand
in the ACU CLI.
Keyword
Abbreviation in ACU
CLI
Keyword
Abbreviation in
ACU CLI
adapterid
ai
nobatterywritecache
nbwc
allunassigned
all
numberparitygroups
npg
arrayaccelerator
aa
parallelscsi
ps
cacheratio
cr
physicaldrive
pd
chassisname*
ch*
postprompttimeout
ppto
chassisserialnumber
csn
preferredpathmode
ppm
chassisslot
chs
queuedepth
qd
configurationmode
cm
raid1writebuffering
r1wb
connectionname
cn
rebuildpriority
rp
controller
ctrl
redundantcontroller
rc
ctrlpath
cp
serialnumber
sn
degradedperformancemode
dpo
spareactivationmode
sam
drivetype
dt
ssdphysicaldrive
ssdpd
drivewritecache
dwc
stripesize
ss
elevatorsort
es
surfaceanalysiseventnotify
saen
enclosure
enc
surfacescandelay
ssd
exitonerror
eoe
surfacescanmode
ssm
expandpriority
ep
sufacescanpriority
sp
inconsistencyrepairpolicy
irp
surfacescanschedule
sss