Controller, CacheState, LicenseKey, DeleteLicenseKey, Video performance options, RebuildPriority

Page 73 highlights

• ClearConfigurationWithDataLoss (on page 74) • DeleteLicenseKey ("LicenseKey, DeleteLicenseKey" on page 74) • DPOEnable ("Video performance options" on page 75) • DriveWriteCache (on page 74) • ElevatorSortEnable ("Video performance options" on page 75) • ExpandPriority ("RebuildPriority, ExpandPriority" on page 75) • IRPEnable ("Video performance options" on page 75) • LicenseKey ("LicenseKey, DeleteLicenseKey" on page 74) • MNPDelay ("Video performance options" on page 75) • NoBatteryWriteCache (on page 74) • PreferredPathMode (on page 74) • QueueDepth ("Video performance options" on page 75) • RaidArrayId (on page 74) • ReadCache ("ReadCache, WriteCache" on page 75) • RebuildPriority ("RebuildPriority, ExpandPriority" on page 75) • SurfaceScanDelay (on page 75) • SurfaceScanDelayExtended (on page 75) • WriteCache ("ReadCache, WriteCache" on page 75) Controller You must enter a value for this option because it identifies the controller that you want to configure: • All-Configure all detected controllers in the system. • First-Configure the first controller found, based on the controller with the lowest PCI slot number. Internal controllers are used before external controllers. The -internal and -external command line switches influence what ACU regards as the First controller. For example, if you use the -external switch, the First controller is the first external controller discovered, regardless of the number of internal controllers in the host system. • Slot [N][:M]-Configure the internal controller in slot number N, or the external controller at port M in slot N. • WWN [N]-Configure the external controller that has the World Wide Name N. • SerialNumber [N]-Configure the shared storage controller that has serial number N. • IOCabinet[N],IOBay[N],IOChassis[N],Slot[N],Cabinet[N],Cell[N]-Configure the controller in the Integrity server that has the slot path information defined by this sequence of identifiers. CacheState This option enables you to flush the cache or disable flushing of the cache. Values are FlushEnable and FlushDisable. HP Array Configuration Utility 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

HP Array Configuration Utility
73
ClearConfigurationWithDataLoss (on page
74
)
DeleteLicenseKey ("
LicenseKey, DeleteLicenseKey
" on page
74
)
DPOEnable ("
Video performance options
" on page
75
)
DriveWriteCache (on page
74
)
ElevatorSortEnable ("
Video performance options
" on page
75
)
ExpandPriority ("
RebuildPriority, ExpandPriority
" on page
75
)
IRPEnable ("
Video performance options
" on page
75
)
LicenseKey ("
LicenseKey, DeleteLicenseKey
" on page
74
)
MNPDelay ("
Video performance options
" on page
75
)
NoBatteryWriteCache (on page
74
)
PreferredPathMode (on page
74
)
QueueDepth ("
Video performance options
" on page
75
)
RaidArrayId (on page
74
)
ReadCache ("
ReadCache, WriteCache
" on page
75
)
RebuildPriority ("
RebuildPriority, ExpandPriority
" on page
75
)
SurfaceScanDelay (on page
75
)
SurfaceScanDelayExtended (on page
75
)
WriteCache ("
ReadCache, WriteCache
" on page
75
)
Controller
You must enter a value for this option because it identifies the controller that you want to configure:
All
—Configure all detected controllers in the system.
First
—Configure the first controller found, based on the controller with the lowest PCI slot number.
Internal controllers are used before external controllers.
The
-internal
and
-external
command line switches influence what ACU regards as the
First
controller. For example, if you use the
-external
switch, the
First
controller is the first external
controller discovered, regardless of the number of internal controllers in the host system.
Slot [
N
][:
M
]
—Configure the internal controller in slot number
N
, or the external controller at port
M
in slot
N
.
WWN [
N
]
—Configure the external controller that has the World Wide Name
N
.
SerialNumber [
N
]
—Configure the shared storage controller that has serial number
N
.
IOCabinet[
N
],IOBay[
N
],IOChassis[
N
],Slot[
N
],Cabinet[
N
],Cell[
N
]
—Configure
the controller in the Integrity server that has the slot path information defined by this sequence of
identifiers.
CacheState
This option enables you to flush the cache or disable flushing of the cache. Values are
FlushEnable
and
FlushDisable
.