HP ProLiant DL280 Configuring Arrays on HP Smart Array Controllers Reference G - Page 91

Invalid Drive Cache setting. Valid options, Cannot delete Logical Drive

Page 91 highlights

Error code 3022 3023 3024 3025 Error message Comment or clarification The connectionname cannot be removed - when the hostmode has a non-default value. Invalid Host Mode - Invalid Adapter ID - This controller does not have host mode - modification capability 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 You need to have administrator rights to - continue. Another instance of ACU is already running - (possibly a service). Please terminate the ACU application before running ACU scripting. Invalid Drive Cache setting. Valid options - are ENABLE and DISABLE. Invalid or out of order Command Verify the ordering of the commands in the input configuration file. Invalid or missing Array for Reconfigure Expecting a valid array in Reconfigure mode Invalid or missing Filename for Firmware Update The firmware filename supplied is not a valid filename. Firmware Update Failed The firmware flash operation on the controller failed. This controller has been configured with a Some changes to SOULAPI are not more recent version of software. To prevent backward-compatible. This check prevents the use of data loss, configuration changes to this an older version of software on a controller controller are not allowed. Please upgrade configured with a newer version, possibly overriding to the latest version to be able to continue to changes and destroying data. configure this controller. Operations on this Array are temporarily The user requested too many simultaneous changes. unavailable while the Array is transforming. For example, the user added new disks to an array (expand array) and changed the size or RAID level of logical volumes on the array. The solution is for the user to wait until the array transformation is complete. Invalid value for NoBatteryWriteCache A problem exists with the NOBATTERYWRITECACHE command. Check the supplied argument. Not all controllers support this operation. Cannot delete Logical Drive A problem occurred during the attempt to delete the specified logical drive. The drive may be in use by the OS, it may not exist, or it may not be the last logical drive on the array. HP Array Configuration Utility 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

HP Array Configuration Utility
91
Error code Error message
Comment or clarification
3022
The
connectionname
cannot be removed
when the
hostmode
has a non-default
value.
3023
Invalid Host Mode
3024
Invalid Adapter ID
3025
This controller does not have host mode
modification capability
3026
You need to have administrator rights to
continue.
3027
Another instance of ACU is already running
(possibly a service). Please terminate the
ACU application before running ACU
scripting.
3028
Invalid Drive Cache setting. Valid options
are ENABLE and DISABLE.
3029
Invalid or out of order Command
Verify the ordering of the commands in the input
configuration file.
3030
Invalid or missing Array for Reconfigure
Expecting a valid array in Reconfigure mode
3031
Invalid or missing Filename for Firmware
Update
The firmware filename supplied is not a valid
filename.
3032
Firmware Update Failed
The firmware flash operation on the controller failed.
3033
This controller has been configured with a
more recent version of software. To prevent
data loss, configuration changes to this
controller are not allowed. Please upgrade
to the latest version to be able to continue to
configure this controller.
Some changes to SOULAPI are not
backward-compatible. This check prevents the use of
an older version of software on a controller
configured with a newer version, possibly overriding
changes and destroying data.
3034
Operations on this Array are temporarily
unavailable while the Array is transforming.
The user requested too many simultaneous changes.
For example, the user added new disks to an array
(expand array) and changed the size or RAID level
of logical volumes on the array. The solution is for the
user to wait until the array transformation is
complete.
3035
Invalid value for NoBatteryWriteCache
A problem exists with the
NOBATTERYWRITECACHE command. Check the
supplied argument. Not all controllers support this
operation.
3036
Cannot delete Logical Drive
A problem occurred during the attempt to delete the
specified logical drive. The drive may be in use by
the OS, it may not exist, or it may not be the last
logical drive on the array.