HP ProLiant DL280 Configuring Arrays on HP Smart Array Controllers Reference G - Page 50

MSA1000 at dog sn: P56350D9IP903J, csn: 9J3CJN71XDCH, wwn

Page 50 highlights

Accelerator Ratio: 10% Read / 90% Write Drive Write Cache: Disabled Total Cache Size: 1024 MB Total Cache Memory Available: 816 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Capacitors Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Spare Activation Mode: Activate on drive failure Controller Temperature (C): 40 Cache Module Temperature (C): 0 Capacitor Temperature (C): 0 Boot Controller: True Primary Boot Volume: logicaldrive 1 Secondary Boot Volume: logicaldrive 1 Example 2 => ctrl all show Because this target consists of several devices, the output will be brief. A typical output would be: MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn: 500805F3000BAC11) Smart Array 5312 in Slot 3 (sn: P4AB5X9BFMLNTJ) Smart Array 532 in Slot 2 (sn: P44940LDAORS4F) Example 3 => ctrl ch="lab4" show config The output in this case will have detailed information because the target consists of only one device. A typical output would be: MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn: 500805F3000BAC11) array A (Parallel SCSI, Unused Space: 20091 MB) logicaldrive 1 (219 MB, RAID 6(ADG), OK) physicaldrive 1:3 (box 1:bay 3, Parallel SCSI, 4.3 GB, OK) physicaldrive 1:4 (box 1:bay 4, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:5 (box 1:bay 5, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:6 (box 1:bay 6, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:7 (box 1:bay 7, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:9 (box 1:bay 9, Parallel SCSI, ??? GB, failed, spare) unassigned drive 1:1 (box 1:bay 1, Parallel SCSI, 36 GB, OK) physicaldrive 1:2 (box 1:bay 2, Parallel SCSI, 36 GB, OK) physicaldrive 1:8 (box 1:bay 8, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:10 (box 1:bay 10, Parallel SCSI, 9.1 GB, OK) HP Array Configuration Utility 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

HP Array Configuration Utility
50
Accelerator Ratio: 10% Read / 90% Write
Drive Write Cache: Disabled
Total Cache Size: 1024 MB
Total Cache Memory Available: 816 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on drive failure
Controller Temperature (C): 40
Cache Module Temperature (C): 0
Capacitor Temperature (C): 0
Boot Controller: True
Primary Boot Volume: logicaldrive 1
Secondary Boot Volume: logicaldrive 1
Example 2
=> ctrl all show
Because this target consists of several devices, the output will be brief. A typical output would be:
MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn:
500805F3000BAC11)
Smart Array 5312 in Slot 3 (sn: P4AB5X9BFMLNTJ)
Smart Array 532 in Slot 2 (sn: P44940LDAORS4F)
Example 3
=> ctrl ch="lab4" show config
The output in this case will have detailed information because the target consists of only one device. A typical
output would be:
MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn:
500805F3000BAC11)
array A (Parallel SCSI, Unused Space: 20091 MB)
logicaldrive 1 (219 MB, RAID 6(ADG), OK)
physicaldrive 1:3 (box 1:bay 3, Parallel SCSI, 4.3 GB, OK)
physicaldrive 1:4 (box 1:bay 4, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:5 (box 1:bay 5, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:6 (box 1:bay 6, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:7 (box 1:bay 7, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:9 (box 1:bay 9, Parallel SCSI, ??? GB, failed, spare)
unassigned
drive 1:1 (box 1:bay 1, Parallel SCSI, 36 GB, OK)
physicaldrive 1:2 (box 1:bay 2, Parallel SCSI, 36 GB, OK)
physicaldrive 1:8 (box 1:bay 8, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:10 (box 1:bay 10, Parallel SCSI, 9.1 GB, OK)