HP ProLiant DL280 Configuring Arrays on HP Smart Array Controllers Reference G - Page 80

PreferredPath, RAID, Renumber, When using an HP Smart Array G6 or G7 controller

Page 80 highlights

The maximum number of parity groups possible for a particular number of physical drives is the total number of drives divided by the minimum number of drives necessary for that RAID level (three for RAID 50, four for RAID 60). PreferredPath If you select the Manual setting for PreferredPathMode (on page 74), use the PreferredPath command to specify the path for I/O to the logical drive on a redundant controller in active/active mode. The default setting for this option is 1. With this setting, the controller in chassis slot 1 is the preferred controller for I/O to the logical drive. If you select 2, the controller in chassis slot 2 becomes the preferred controller for the logical drive. To determine the chassis slot numbers, use the show command on a controller that supports redundant controllers. RAID The value that you enter for this option specifies the RAID level of the logical drive. • When the Action mode is Configure and the Method mode is Auto, ACU automatically selects the highest RAID level that the controller and drive configuration can support except RAID 50 or RAID 60. To specify RAID 50 or 60 for a controller that supports either of these RAID levels, use the Custom setting. In this case, you must also specify the number of parity groups ("NumberOfParityGroups" on page 79). • When the Action mode is Reconfigure, the default value is the existing RAID level for that logical drive. If you specify a different RAID setting, then ACU either ignores the new setting (when Method mode is Auto) or attempts to migrate the logical drive to the specified RAID level (when Method mode is Custom). ACU supports the following values for RAID levels: • 60-RAID 60 • 50-RAID 50 • ADG-RAID ADG is the equivalent of RAID 6 • 6-RAID 6 • 5-RAID 5 • 4-RAID 4 • 10ADM-RAID 1 with 3-way mirroring • 10-RAID 10 (mirroring with 2 disks) • 1ADM-RAID 1 with 3-way mirroring • 1-RAID 1 (mirroring with 2 disks) • 0-RAID 0 When using an HP Smart Array G6 or G7 controller, some RAID levels require SAAP ("About SAAP" on page 8). Renumber This option renumbers the logical drive to N. HP Array Configuration Utility 80

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

HP Array Configuration Utility
80
The maximum number of parity groups possible for a particular number of physical drives is the total number
of drives divided by the minimum number of drives necessary for that RAID level (three for RAID 50, four for
RAID 60).
PreferredPath
If you select the Manual setting for
PreferredPathMode
(on page
74
), use the
PreferredPath
command to specify the path for I/O to the logical drive on a redundant controller in active/active mode.
The default setting for this option is
1.
With this setting, the controller in chassis slot 1 is the preferred
controller for I/O to the logical drive. If you select
2,
the controller in chassis slot 2 becomes the preferred
controller for the logical drive.
To determine the chassis slot numbers, use the
show
command on a controller that supports redundant
controllers.
RAID
The value that you enter for this option specifies the RAID level of the logical drive.
When the Action mode is Configure and the Method mode is Auto, ACU automatically selects the
highest RAID level that the controller and drive configuration can support except RAID 50 or RAID 60.
To specify RAID 50 or 60 for a controller that supports either of these RAID levels, use the Custom
setting. In this case, you must also specify the number of parity groups ("
NumberOfParityGroups
" on
page
79
).
When the Action mode is Reconfigure, the default value is the existing RAID level for that logical drive.
If you specify a different RAID setting, then ACU either ignores the new setting (when Method mode is
Auto) or attempts to migrate the logical drive to the specified RAID level (when Method mode is
Custom).
ACU supports the following values for RAID levels:
60
—RAID 60
50
—RAID 50
ADG
—RAID ADG is the equivalent of RAID 6
6
—RAID 6
5
—RAID 5
4
—RAID 4
10ADM
—RAID 1 with 3-way mirroring
10
—RAID 10 (mirroring with 2 disks)
1ADM
—RAID 1 with 3-way mirroring
1
—RAID 1 (mirroring with 2 disks)
0
—RAID 0
When using an HP Smart Array G6 or G7 controller, some RAID levels require SAAP ("
About SAAP
" on
page
8
).
Renumber
This option renumbers the logical drive to
N
.