HP ProLiant DL280 Configuring Arrays on HP Smart Array Controllers Reference G - Page 61
Spare Management Mode in HPACUCLI, Expanding an array, Syntax, Example commands, Command example
View all HP ProLiant DL280 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
• When a data drive fails; this mode is the default. In normal operations, and for older controllers, the firmware starts rebuilding a spare drive only when a data drive fails. With the predictive failure activation mode, rebuilding can begin before the drive fails, reducing the likelihood of data loss that could occur if an additional drive fails. Use the spareactivationmode keyword to toggle the spare activation mode for the controller between drive failure and drive predictive failure. Syntax: modify spareactivationmode=[ failure | predictive ] Example commands: controller slot=1 modify spareactivationmode=predictive controller slot=1 modify spareactivationmode=failure Spare Management Mode in HPACUCLI The sparetype keyword allows you to specify the spare type as "dedicated" (default) or "autoreplace." A dedicated spare temporarily takes over for a failed drive and can be shared between arrays. An autoreplace spare replaces a failed drive and cannot be shared between arrays. Command example: To add a spare with spare type of autoreplace: => ctrl slot=1 array A add spares=1e:1:5 sparetype=autoreplace Expanding an array You can increase the storage space on an array by adding physical drives. Any drive that you want to add must meet the following criteria: • It must be an unassigned drive. • It must be of the same type as existing drives in the array (for example, SATA or SAS). • It must have a capacity no less than that of the smallest drive in the array. IMPORTANT: An array expansion, logical drive extension, or logical drive migration takes about 15 minutes per gigabyte. While this process is occurring, no other expansion, extension, or migration can occur simultaneously on the same controller. Controllers that do not support a battery-backed write cache do not support this process. Syntax: add drives allunassigned [forced] where is an array (or a logical drive, if the array contains only one logical drive). The forced parameter represses any warning message prompts. If you specify a drive range, any drives in the range that do not meet the previous criteria are not used. If you add an odd number of drives to an array that contains a RAID 1+0 logical drive, you are prompted to convert the RAID 1+0 logical drive to RAID 5 or RAID 6 (ADG). Adding the forced parameter to the command prevents this prompt from appearing. Example commands: => ctrl slot=3 array A add drives=1:0,1:1 => ctrl slot=4 ld 1 add drives=allunassigned => ctrl slot=5 array A add drives=1:1-1:5 HP Array Configuration Utility 61