IBM 8651RM0 Hardware Maintenance Manual - Page 14
Is The System Part Of A Cluster?, Did You Receive The Correct Responses?
UPC - 087944340508
View all IBM 8651RM0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
(CONTINUED) 001 IS THE SYSTEM PART OF A CLUSTER? Yes No 002 Go to Step 004. 003 Schedule maintenance with the customer. Shut down all systems related to the cluster. Run storage test. 004 Note Use the Setup program to define the CD-ROM drive as the First Boot Device. Refer to "Defining the Startup Device" on page 44 - Power-off the computer and all external devices. - Check all cables and power cords. - Set all display controls to the middle position. - Power-on all external devices. - Power-on the computer. - Insert the System CD-ROM into the CD-ROM drive; then, press Ctrl+Alt+Del. - Check for the following responses: 1. One beep. 2. Readable instructions or the Main Menu. DID YOU RECEIVE THE CORRECT RESPONSES? Yes No 005 Find the failure symptom in "Symptom-to-FRU Index" on page 156. 006 - Run the Netfinity 7000 Diagnostics Test. If necessary, refer to "Starting the Diagnostic Programs" on page 13 and "Using the Test Selection" on page 14. If you receive an error, go to "Symptom-to-FRU Index" on page 156. 6 Netfinity Server HMM