Error Code 0191 (CMOS battery failed) 0195 (CMOS system options not set) 0198 (CMOS checksum invalid) 0200 (Invalid voltage jumper for processor in Slot 1 Processor 1) 0201 (Invalid voltage jumper for processor in Slot 1 Processor 2) 0202 (Invalid voltage jumper for processor in Slot 2 Processor 1) 0203 (Invalid voltage jumper for processor in Slot 2 Processor 2) 0204 (CPU Removed - Slot 1 CPU 1) 0205 (CPU Removed - Slot 1 CPU 2) 0206 (CPU Removed - Slot 2 CPU 1) 0207 (CPU Removed - Slot 2 CPU 2) 0208 (CPU not responding - Slot 1 CPU 1) 0209 (CPU not responding - Slot 1 CPU 2) 0210 (CPU not responding - Slot 2 CPU 1) 0211 (CPU not responding - Slot 2 CPU 2) 0220 (Fan Failure Slot 1 Processor 1) FRU/Action 1. Real-Time Clock Module 2. System Board 1. Run System Configuration Utility program 1. Run System Configuration Utility program 1. Check jumper settings 1. Check jumper settings 1. Check jumper settings 1. Check jumper settings 1. Information only 1. Information only 1. Information only 1. Information only 1. Processor 1 on Processor Board 1 1. Processor 2 on Processor Board 1 1. Processor 1 on Processor Board 2 1. Processor 2 on Processor Board 2 1. Fan Heat Sink on Processor 1 on Processor Board 1 IBM Netfinity 7000 - Type 8651 161