IBM 8651RM0 Hardware Maintenance Manual - Page 78
Control Panel FRUs
![]() |
UPC - 087944340508
View all IBM 8651RM0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
Control Panel FRUs 70 Netfinity Server HMM Intrusion Switch Connectors Jumper pins 1 and 2 to bypass switch connectors J4 and J5. Jumper pins 2 and 3 to enable switch connectors J4 and J5. J4 J5 J14 J9 Control Card NMI Reset Power ON/OFF CR1: Power-On Light Green: Server Powered On CR2: Power Failure Light Amber Blinking: Power Subsystem Failure (Refer to trouble shooting the Power Supply section) CR3: Cooling Failure Light Amber Blinking: - One or more fans have failed - Ambient temperature is outside normal operating range (35 oC) CR4: Hot-Swap Drive Subsystem Failure Light Amber Blinking: - Hard Drive has failed or - Hard drive temperature is outside operating range (60 oC) CR1 CR4 CR2 CR3 LED Card VFD
![](/manual_guide/products/ibm-8651rm0-hardware-maintenance-manual-d671fe8/78.png)
Control Panel FRUs
CR1: Power-On Light
Green: Server Powered On
CR2: Power Failure Light
Amber Blinking: Power Subsystem Failure
(Refer to trouble shooting the Power Supply section)
CR3: Cooling Failure Light
Amber Blinking:
- One or more fans have failed
- Ambient temperature is outside normal operating range (35 C)
o
CR4: Hot-Swap Drive Subsystem Failure Light
Amber Blinking:
- Hard Drive has failed or
- Hard drive temperature is outside operating range (60 C)
o
LED Card
VFD
Control Card
Intrusion Switch
Connectors
Jumper pins 1 and 2 to
bypass switch connectors
J4 and J5.
Jumper pins
2 and 3 to enable switch
connectors J4 and J5.
CR2
CR3
CR4
NMI
Reset
Power ON/OFF
CR1
J14
J4
J9
J5
70
Netfinity Server HMM