IBM 8651RM0 Hardware Maintenance Manual - Page 39
Table 2. Adapter LED Indicators
UPC - 087944340508
View all IBM 8651RM0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Flash Utility Select one: Configure Advanced System Management Adapter View Advanced System Management Adapter Configuration Update Advanced System Management Adapter Set Up COM Ports Configure OS Watchdog Timer Exit Enter F1=Help F3=Exit 7. Check the dot on the two LED displays on the adapter for the indications listed in Table 2. Battery CR1 CR2 Table 2. Adapter LED Indicators CR1 Dot On CR1 Dot Off Problem indication. Normal. Check CR2 Dot. CR2 Dot Blinking CR2 Dot Off Normal; microcode is loaded. Go to step 8. Microcode is not loaded. Select Update Service Processor on the Flash Utility menu and follow the prompts. Then return to step 7. 8. Refer to the configuration data you recorded and complete the following steps. a. Choose Configure Advanced System Management Adapter from the Flash Utility menu and select the port and IRQ that you entered in the configuration data worksheet. The utility program writes an SM.INI file to the diskette. This file is used during the device driver installation. b. Follow the on-screen prompts and choose Setup COM Ports from the Flash Utility menu. Select the COM port I/O addresses and interrupts that you entered on the configuration worksheet. 9. Follow the on-screen prompts to exit from the adapter configuration utility program. 10. Replace the server top cover. IBM Netfinity 7000 - Type 8651 31