IBM 8681 Hardware Maintenance Manual - Page 193
Failed RAID test on PCI, Failed Microprocessor test
UPC - 087944642503
View all IBM 8681 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 193 highlights
Error Code/Symptom 035-XXX-Y99 (Failed RAID test on PCI slot Y. Check system error log before replacing a FRU.) 035-253-Y99 (RAID adapter initialization failure) 035-XXX-YNN (Fixed disk error at SCSI ID NN on slot Y. Check system error log before replacing a FRU.) 089-XXX-001 (Failed Microprocessor test) 089-XXX-002 (Failed Microprocessor test) 089-XXX-003 (Failed Microprocessor test) FRU/Action 1. RAID Adapter in slot Y 2. SCSI Backplane 3. Cable 1. ServeRAID adapter in slot Y is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID HMM for more information. 1. Fixed disk with SCSI ID NN on RAID adapter in PCI slot Y 1. Cache Coherency DIMMs, if two Processor Daughter Boards are installed. Disregard if a single Processor Daughter Board is installed. 2. Processor B1 3. Processor Daughter Board B 4. Processor Controller Board 1. Cache Coherency DIMMs, if two Processor Daughter Boards are installed. Disregard if a single Processor Daughter Board is installed. 2. Processor B2 3. Processor Daughter Board B 4. Processor Controller Card 1. Cache Coherency DIMMs, if two Processor Daughter Boards are installed. Disregard if a single Processor Daughter Board is installed. 2. Processor B3 3. Processor Daughter Board B 4. Processor Controller Card Netfinity 8500R - Type 8681 185