IBM 8681 Hardware Maintenance Manual - Page 206
I/O Board Cable, Fixed Disk Cables
UPC - 087944642503
View all IBM 8681 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 206 highlights
Error Code/Symptom 605 (Unlock failure) 662 (Diskette drive configuration error) 762 (Coprocessor configuration error) 962 (Parallel port error) 11XX (System board serial port 1 or 2 error) 1600 (The System Management Adapter is not functioning) Do the following before replacing a FRU: Remove the ac power to the system, wait 20 seconds; then, re-connect the ac power. Wait 30 seconds; then, power-on the system. 1762 (Fixed Disk Configuration error) 178X (Fixed Disk error) 1800 (No more hardware interrupt available for PCI adapter) FRU/Action 1. Check drive cable 2. Diskette Drive 3. Media Power Cable 4. I/O Function Card 1. Run Configuration/Setup and Diagnostics 2. Check Drive cable 3. Diskette Drive 4. Media Power Cable 5. I/O Function Card 1. Run Configuration/Setup 2. Battery, see "Battery replacement" on page 49. 3. BSP Processor 1. Disconnect external cable on parallel port. 2. Run Configuration/Setup 3. I/O Function Card 1. Disconnect external cable on serial port. 2. Run Configuration/Setup 3. I/O Function Card 1. I/O Board Cable 2. System Management Adapter Cable 3. System Management Adapter 4. I/O Function Card 5. I/O Board 1. Fixed Disk Cables 2. Run Configuration/Setup 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. I/O Function Card 1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. I/O Function Card 1. See system error log. 2. See error code 001800XX 198 Netfinity Server HMM